Step 7 - Setting Zones Types (Location 1)
There are 8 zones for each partition. We use partition 1 in this example; settings for other
partitions are similar. The pre-delivery values of the zones is shown below. It should satisfy
most installations.
Zone
(Sub-location)
Default Value
1
01
PRIMARY ENTRY/EXIT
ZONE
2
02
FOLLOWER ZONE
3
04
INSTANT ZONE
4
04
INSTANT ZONE
5
04
INSTANT ZONE
6
04
INSTANT ZONE
7
04
INSTANT ZONE
8
04
INSTANT ZONE
If necessary, installers can also change the zone type. Please refer to the table below for the
value of different zone types.
The input format is:
[Installer Code] [*] [1] [*] [Zone Number] [*] [Zone Type] [*]…[#] [#]
Zone Type
Value
Zone Type
Value
DISABLED
0
Instant Fire Zone(New)
9
PRIMARY ENTRY/EXIT ZONE
1
FIRE ZONE
10
FOLLOWER ZONE
2
TAMPER ZONE
11
PANIC/PRIORITY ZONE
3
24 HOUR ALARM ZONE
12
INSTANT ZONE
4
WARNING ZONE
13
ARM/DISARM ZONE
5
PUSH TO ARM ZONE
14
SECONDARY ENTRY/EXIT ZONE
8
OUTDOOR INSTANT ZONE
15
For example, if you don’t need follower zone and zone 7 and 8 are not used, you can change
Zone 2 (default Follower Zone) to instant zone and disable zone 7 and 8.
Enter:
1479*
1*
2*
4*
7*
0*
8*
0*
Installer
code
Location
1
(Zone
Types)
Zone 2
Instant
zone
Zone 7
Disable
Zone 8
Disable
and then press # # to exit installer menu.
i.e. enter:
1479* 1* 2* 4* 7* 0* 8* 0* # #