Step 11 - Setting Communication Delay and Number of Dial Attempts
Numbers
By default, the alarm panel will dial the phone numbers stored at location 51-54(Telephone
Number 1-4) after 20 seconds when it is triggered. It attempts to dial maximum of 6 times. If
the alarm condition is cancelled within this time, it will not report. If you want to change
these parameters, follow the steps below:
Setting Communication Delay
Enter 1479* to enter the installer menu.
When you see
Action
INSTALLER MENU
Location:***
Enter
45*
Comms Delay
Update Time: (Current Setting)
Input the new communication delay in mm:ss
format and press *
mm=minute, ss=second
e.g. If we want to change the delay to 30 seconds,
enter:
00:30*
INSTALLER MENU
Location:***
Press
#
to exit setting
Setting Number of Dial Attempts Numbers
Enter 1479* to enter the installer menu.
When you see
Action
INSTALLER MENU
Location:***
Enter
47*
Dial Attempts
Update Data: (Current Setting)
Input the Number of Dial Attempts Numbers
and press *
e.g. To set 5 attempts, enter:
5*
Valid range of data: 1 – 9, with 0 to disable.
INSTALLER MENU
Location:***
Press
#
to exit setting
Step 12 - Changing the Installer Code (Location 197)
Be careful:
After changing the installer code, this new code must be used to administer
the panel – if the code is lost, the panel must be defaulted with all configurations lost.
Enter:
1479* 197* [New Installer Code] * #