background image

+

Watchguard WGAP864

Quick Installation Guide

v1.12 – Revised 13

th

February 2018

Summary of Contents for WGAP864

Page 1: ... Watchguard WGAP864 Quick Installation Guide v1 12 Revised 13th February 2018 ...

Page 2: ......

Page 3: ...ng Information Location 25 31 4 Step 4 Exit Delay Location 230 5 Step 5 Primary Entry Delay Location 231 5 Step 6 Setting Siren Time Out Period Location 17 5 Step 7 Setting Zones Types Location 1 6 Step 8 Managing User Codes 7 Programmable Outputs 9 Optional Settings 9 Step 9 Setting Account Codes Location 61 Partition 1 9 Step 10 Setting Phone Numbers Location 51 54 9 Step 11 Setting Communicatio...

Page 4: ...istor has to be installed so that the electrical current will complete a loop from the alarm panel zone input to the sensor The alarm panel monitors the current flow through the loop If someone tries to tamper by cutting or shorting circuit the loop wiring the alarm panel will detect the current change and will trigger the alarm panel For normal zones the EOL resistor is 3k3 ohm For tamper zones t...

Page 5: ...ed by the system Installer Menu With alarm panel in disarm state enter Installer Code to enter installer menu The LCD will show To go back to previous menu press The standard format to input data to a location is Installer Code Location number Data The system will exit installer menu and go back to home screen when is pressed However you can also enter location and data continuously without having...

Page 6: ...tant 04 Zone 7 Instant 04 Zone 4 Instant 04 Zone 8 Instant 04 Programmable Outputs LOCATION 390 414 Zone Signal Output 1 PANIC HIGH for 2 seconds Output 2 STROBE HIGH for 2 seconds Output 3 ARM HIGH DISARM LOW Output 4 FIRE HIGH for 2 seconds Output 5 MEDICAL HIGH for 2 seconds Trouble Display Location 16 Data Action Default 1 AC fail trouble display ON 4 On board siren monitoring trouble display ...

Page 7: ...nd then release the keys no beep sound 6 The keypad is unregistered and the LCD on the keypad will show Unreg Step 2 Setting Date and Time Must do this BEFORE proceeding to Step 4 because the LCD keeps reminding you to set up date and time Press and hold button to enter the User Menu When you see Enter 1835 40 hhmm 41 ddmmyy where hh hour in 24 hour format 00 23 mm minute 00 59 ddmmyy day 01 31 mo...

Page 8: ...anel Please Wait and exit the installer menu Step 4 Exit Delay Location 230 Default value 30 seconds Ignore if don t need to change Enter 1479 230 Partition Number mmss Example 1479 230 1 0100 sets exit delay of Partition 1 Zone1 8 to 1 minute 0 seconds Step 5 Primary Entry Delay Location 231 Default value 30 seconds Ignore if don t need to change Enter 1479 231 Partition Number mmss Example 1479 ...

Page 9: ...le below for the value of different zone types The input format is Installer Code 1 Zone Number Zone Type Zone Type Value Zone Type Value DISABLED 0 Instant Fire Zone New 9 PRIMARY ENTRY EXIT ZONE 1 FIRE ZONE 10 FOLLOWER ZONE 2 TAMPER ZONE 11 PANIC PRIORITY ZONE 3 24 HOUR ALARM ZONE 12 INSTANT ZONE 4 WARNING ZONE 13 ARM DISARM ZONE 5 PUSH TO ARM ZONE 14 SECONDARY ENTRY EXIT ZONE 8 OUTDOOR INSTANT ...

Page 10: ... to installer menus Installer Code 1479 or 147999 Full access to all installer mode menus Adding User Code Press and hold button to enter User Menu When you see Action Master Code Enter 1835 Add User Code 0 New Code Input the new user code All users must have different code New User Code 1 After that a short beep will be heard to indicate user code is added successfully New Code New User Code 2 an...

Page 11: ...u When you see Action Master Code Enter 1835 Add User Code 2 User Code Input the user code you want to delete User Code User Code Press to exit User Menu Example Delete user codes 1567 and 2450 Enter HOLD 1835 2 1567 2450 Delete all User Codes Location 0 Value 2 Enter 1479 0 2 All user codes will be cleared and Master Code User Code 1 will reset to 1234 or 123456 ...

Page 12: ...ogrammable outputs are primarily connected to trigger external device inputs but not to drive external devices The Watchguard Relay Board P N WGAPARB must be used for connecting LEDs sirens bus wired peripherals etc There are many locations and values for setting the programmable outputs Please read Installer Manual for more detailed information Optional Settings Skip steps 9 11 if dailer is not i...

Page 13: ...nput the new communication delay in mm ss format and press mm minute ss second e g If we want to change the delay to 30 seconds enter 00 30 INSTALLER MENU Location Press to exit setting Setting Number of Dial Attempts Numbers Enter 1479 to enter the installer menu When you see Action INSTALLER MENU Location Enter 47 Dial Attempts Update Data Current Setting Input the Number of Dial Attempts Number...

Reviews: