ART-SD3792A-00, REV.00 

The smoke alarm is operating once the power is connected and turned on (the battery must 
also be installed).  When products of combustion are sensed, the unit sounds a loud alarm 
which continues until the air is cleared. 
 
FALSE ALARM “SILENCE” CONTROL 
 
Units with the ‘silence’ feature have the capability of temporarily reducing the sensitivity of 
the alarm circuit for approximately 8 minutes.  This feature is to be used only when a known 
alarm condition such as smoke from cooking activates the smoke alarm.  The smoke alarm is 
deactivated by pushing the hush button on the smoke alarm once.  The smoke alarm will 
automatically reduce sensitivity and light up the red indicator for approximately 8 minutes to 
indicate the alarm is in the temporary silent condition.  It will reactivate after such 8 minutes 
and sound the alarm if particles of combustion are still present.  The “silence” feature may be 
used repeatedly until the air has cleared. 

 
CAUTION: Before using the alarm “silence” feature, identify the source of smoke and 
be certain that safe conditions exist. 

 
TESTING 
 
Test by pressing the test button on the smoke alarm cover for at least four seconds, until the 
alarm sounds.  It activates the self-test program and the alarm sounds if all electronic 
circuitry, horn and battery are working.  When any smoke alarm is tested, all interconnected 
units should sound an alarm. 

Highly recommend to test the alarm weekly to assure 

proper operation

.  In case of no alarm sounds on test, and/ or the unit has a defective 

battery, then try to replace the battery by a new one.  You can also test the alarm by blowing 
smoke into the unit.  
 
PLEASE DISPOSE OFF THE BAD OR DISCHARGED BATTERIES PROPERLY TO 
PROTECT OUR ENVIRONMENT. 
 
MAINTENANCE 
 
The smoke alarm is virtually maintenance free.  However, under dusty conditions, a vacuum 
hose may be used to clear the dust through the side opening.  It is recommended to clean the 
alarm monthly to keep best performance.  Normally, the alarm can be operated up to 10 
years without replacement.  See the replacing date on the bottom of alarm unit. 

 
BATTERY REPLACEMENT 

 
The power of this smoke alarm is backup by one 9VDC battery.  The battery should last for 
at least one year under normal operating conditions.  The smoke alarm has a low battery 
indicator, and audible "chirp".  It will operate at 30 - 40 second intervals for a minimum of 7 
days.  

Replace the battery when this indication occurs.

  Only following 9VDC batteries 

(available at most drug, hardware or electronic parts stores) may be used for replacement. 

 
Carbon-Zinc Type: Eveready #216; Gold Peak #1604P; Gold Peak #1604S; Gold Peak 

#1604G. 

Alkaline Type: 

Eveready Energizer #522; Gold Peak #1604A; Duracell #MN1604. 

Lithium Type: 

Ultralife U9VL-J 

 

GOOD SAFETY HABITS 
 

There are situations where a smoke alarm may not be effective in protecting against fire, for 
instance: 
 
*

 

Smoking in bed; 

*

 

Leaving children home alone; and 

*

 

Cleaning with flammable liquids, such as gasoline. 

 
 
 
 

WARNING 
Disposal of unit - The unit contains a small quantity of radioactive source 
Americium 241, 1.0 microcurie.  Return to supplier or Department of Health in 
your state for disposal by courier or hand delivery.  Do not send smoke alarm by 
Australia Post. 
Alternative disposal is not permitted. 
Do not try to tamper with sealed source.  

 
ELECTRICAL RATING 

 
MAINS POWER 
Operating voltage (Max.):  220-240VAC, 50Hz 
Operating current (Max.):  80mA 
 
BACKUP BATTERY 
Operating voltage (Max.):  9VDC 
Operating current (Max.):  20mA 
Battery type: 

6F22 

 
 
 
 
 
 
 
 
 