ART-SD3792A-00, REV.00
*
Leave immediately by your plan of escape. Every second counts, so don't waste time
getting dressed or picking up valuables.
*
In leaving, don't open any inside door without first feeling its surface. If not, or if you
see smoke seeping through cracks, don't open that door! Instead, use your alternate exit.
If inside door is cool, place your shoulder against it, open it slightly and be ready to slam
it shut if heat and smoke rush in.
*
Stay close to the floor if air is smoky. Breathe shallowly through a cloth, wet if possible.
*
Once outside, go to your selected meeting place and make sure everyone is there.
*
Call the fire department from your neighbor's home - not from yours.
*
Don't return to your home until fire officials say that it is all right to do so.
FALSE ALARMS
The smoke alarm is designed to minimize false alarms. Smoking will not normally set off
the alarm unless smoke is blown directly into the smoke alarm. Combustion particles from
cooking may set off the alarm if the smoke alarm is located close to the kitchen cooking
surface. Large quantities of combustion particles are generated from spills or broiling.
If the smoke alarm does sound, check for fires first.
If a fire is discovered, get out and
call the fire department. If no fire is present, check to see if one of the reasons listed above
may have caused the alarm.
INSTALLATION AND MOUNTING INFORMATION
The alarm must be installed by licensed electrical contractor only!
The smoke alarm will function correctly either as a stand-alone alarm or inter-connected.
All inter-connected smoke alarms must be supplied from a single power circuit.
Do not connect Inter-connect wire to Live or Neutral.
Do not connect the smoke alarm to a circuit protected by a Residual Current Device.
Connect and powered the smoke alarm with 220-240VAC only.
Solid wires with 1mm
2
(or larger) cross-section area are recommended for power supply and
inter-connection. Strip the Live, Neutral, and Inter-connect wires back to the length of
10mm. Connect the wires to the terminals in the wall mount and ensure the screws are fully
tightened. The colors of wires are: Live=Brown; Neutral=Blue, Inter-connect=White. The
smoke alarms can be inter-connected as many as 20 units in series.
Check the connections
carefully before closing the junction box. Incorrect connection may damage the unit.
Your smoke alarm is designed for easy mounting on wall or ceiling. Ideally, this smoke
alarm is designed for mounting on standard flush box (84mm mounting centers). Place the
mounting bracket on it and locate the screw-holes of flush box. Then attach the bracket
directly on it with the screws provided. Then, check the mounting firmly.
For mounting without standard flush box, place the mounting bracket on the wall or ceiling
surface, use the pencil to mark down two drill-holes location on it. Usually, the distance
between two centers of drill-holes should be 84mm. For wooden surface, attach the bracket
directly on it with the screws provided. For the concrete surface or masonry, use drilling
machine to drill these two holes on the surface firstly. The sizes of holes are around 5.5mm
diameter and 25-30mm deep. Insert two dowels into the drilled holes before attached the
bracket. Then, check the mounting firmly.
Insert a 9VDC battery. Fold the alarm to wall mount tightly.
The alarm cannot be hooked
if the battery is not installed properly.
Green LED will be brightened. Press TEST button to check the alarms work. Inter-
connected alarms must also be checked.
Do not leave installation until the alarms have
been checked for correct operation.
During power up the unit, several ‘beep’ alarming may happen. It is normal operation
for the unit.
OPERATION, TESTING & MAINTENANCE
OPERATION