14
3.2. AWAY Mode
When to use
This mode is used when leaving the building or premise, i.e.
AWAY
from premises.
Arming the system in this mode will activate all detectors.
Indications
The siren will beep once and the strobe will flash for 2 seconds. There will be a 20
second delay before the system is fully armed. During this delay only the 24 hour
detectors (e.g. smoke detectors) and tamper signals will trigger the alarm. If any extra
beeps are heard,
see section 3.7 (Supervision Reporting)
.
Triggering
If a detector is triggered, when the system is fully armed, the alarm will sound for 5
minutes or until the system is disarmed (which ever occurs first). Each detector zone
can only trigger the siren once, in one arming period.
3.3. STAY Mode
When to use
This mode is used for protecting only a selected area(s) of the building while you (and
others) are on the premises or someone is
STAYING
home. Commonly used at night
while sleeping.
Indications
The siren will beep once on the first press and will then make a low tone beep the on
the second press. There will be a 20 second delay before the system is armed in STAY
mode. If any extra beeps are heard,
see section 3.7 (Supervision Reporting)
.
Triggering
Arming the system in this mode will enable zone 1 (default), and other extra detectors
that have been set to trigger the alarm in STAY mode. When any stay mode detector is
triggered in this mode after the 20 second exit delay the siren will beep 5 times.
3.4. DISARMING
When to use
The system should be disarmed before entering the building or premise.
Indications
The siren will beep twice and the strobe will flash for 5 seconds. The siren will beep 4
times instead of twice, if the alarm has been triggered while the system was armed. If
any extra beeps are heard,
see section 3.6 (Low Battery Reporting)
.