background image

WatchGuard AP330 Hardware Guide

WEEE Statement

WEEE is a general set of requirements dictated in the EU Directive 2002/96/EC. This Directive mandated
that member EU countries enact regulations governing the Waste of Electrical and Electronic Equipment
(WEEE). The Directive, and its individual transpositions into specific country laws and legislation, is aimed
at the reduction of WEEE through reuse, recovery, and recycling of WEEE.

WatchGuard is working in partnership with our European Union (EU) distribution partners to ensure that our
products are in compliance with the WEEE statutes, and that the recovery of our product per the specific
EU country legislative requirements is seamless for our product’s end users. If you have a WatchGuard
product that is at its end of life and needs to be disposed of, please contact WatchGuard Customer Care
Department at:

U.S. Customers: 877.232.3531
International Customers: +1.206.613.0456

WatchGuard is reasonably confident that our products do not contain any substances or hazardous
materials presently banned by any legislation, and do not present a risk due to hazardous materials. WEEE
recovery professionals should also note that these products do not have any materials that are of particular
high value in their individual form.

REACH Certificate of Compliance

The new EU chemicals policy REACH (Registration, Evaluation, Authorization and restriction of
Chemicals) came into effect on June 1, 2007. REACH is Europe's new chemicals legislation, which is
applicable in all 27 EU Member States as well as the EFTA European Economic Area (EEA). REACH
creates a new system for gathering information, assessing risks to human health and the environment, and
authorizing or restricting the marketing and use of chemicals produced or supplied in the EEA. REACH has
an impact on EEA producers and importers of finished products and users of chemicals in the course of
industrial or professional activities.

WatchGuard supports the overall REACH objective of improving the protection of human health and the
environment and will meet all applicable REACH requirements. WatchGuard is strongly committed to
working with our customers and supply chain to define and implement the REACH requirements and ensure
a smooth transition to compliance.

One of the REACH requirements is that manufacturers and importers have the duty to register substances
they are producing or importing. In accordance with the regulations, the products of WatchGuard do not
need to be registered for the following reasons:

n

WatchGuard does not import more than 1 metric ton per year of a substance as defined by REACH.

n

WatchGuard products are non-chemical products that are not designed to release any substance under
normal and reasonably predictable application.

n

Our products do not contain the listed substances at more than 0.1% by weight of the whole
product/part.

WatchGuard Technologies, Inc.

21

Summary of Contents for AP330

Page 1: ...WatchGuard AP330 Hardware Guide AP330 Access Point ...

Page 2: ...WatchGuard Technologies Inc 2 ...

Page 3: ...ty providing best in class Unified Threat Management Next Generation Firewall secure Wi Fi and network intelligence products and services to more than 75 000 customers worldwide The company s mission is to make enterprise grade security accessible to companies of all types and sizes through simplicity making WatchGuard an ideal solution for Distributed Enterprises and SMBs WatchGuard is headquarte...

Page 4: ...ator 6 Mount and Connect the AP 7 Ceiling Mount 8 Wall Mount 9 Wall Mount with T Rail Mount and Spacers 10 Connect the AP 11 Power Adapter Optional 12 Ethernet Power Injector Optional 13 Notices 15 Safety Warning 15 Power Adapter Requirements 15 FCC Certification 15 CE Notice 16 Industry Canada Certification 16 EU Declaration of Conformity 18 Brazil ANATEL 20 Mexico NOM 20 Japan Statement 20 ii Wa...

Page 5: ...Japan VCCI Class B Statement 20 Taiwan NCC Statement 20 RoHS Statement 20 WEEE Statement 21 REACH Certificate of Compliance 21 WatchGuard Technologies Inc iii ...

Page 6: ...te on the 2 4GHz band and 1200 Mbps on the 5GHz band The AP330 also has a third radio dedicated to security scanning AP Management You can manage your AP330 with WatchGuard Cloud a powerful cloud based enterprise wireless management solution for AP configuration security and monitoring For more information on how to set up your AP with WatchGuard Cloud see watchguard com start WatchGuard Technolog...

Page 7: ...equency Band n Radio 1 2 4 GHz 2x2 11b g n ax n Radio 2 5 GHz 2x2 11a n ac ax n Radio 3 Scan Dual Band 802 11ac Wave 1 2x2 radio Antennas n Wi Fi 2 x Min 2dBi 2 4GHz 2 x Min 2dBi 5GHz internal antennas n Scan Radio 2 x Min 2dBi 2 4 5GHz dual band internal antenna n BLE 1 x Min 2dBi 2 4GHz internal antenna Ethernet Interfaces n 2 5GbE Ethernet port Power Interface n PoE 48 57V DC 802 3at n 12V 2A D...

Page 8: ...evice indoors n Make sure the device has adequate clearance for air flow and cooling Other environmental requirements Operating Temperature 0 C to 40 C 32 F to 104 F Operating Humidity 5 to 95 non condensing Non operating Temperature 20 C to 65 C 4 F to 149 F Non operating Humidity 5 to 95 non condensing WatchGuard Technologies Inc 3 ...

Page 9: ...e reset button for up to 10 seconds When you release the reset button all LEDs will go off to indicate that the AP has rebooted USB Port This port is currently not in use Serial Console RJ 45 port is for serial console connections to the access point LAN POE This is an LAN port that connects the AP to a wired LAN connection through a switch or hub This port also provides PoE 802 3at power for the ...

Page 10: ...WatchGuard AP330 Hardware Guide DC 12V If PoE power is unavailable you can power the device with the optional 12V DC power adapter WG9009 WatchGuard Technologies Inc 5 ...

Page 11: ...e AP330 has a single LED indicator that can show these conditions LED Color Status Solid Orange AP is booting Permanent orange indicates a hardware issue Flashing Orange AP cannot connect to WatchGuard Cloud Solid blue AP is online Flashing blue Flash LED action from WatchGuard Cloud WatchGuard AP330 Hardware Guide 6 WatchGuard Technologies Inc ...

Page 12: ...e includes the AP330 ceiling mount t rail brackets and wall mount screws and spacers The MAC address and serial number of your AP are printed on a label on the back of the device Make sure you record this information before you mount the AP WatchGuard Technologies Inc 7 ...

Page 13: ... back panel of the access point 2 Hold the access point with one hand to reach the other hand over the t rail sides of the bracket 3 Attach the stationary end of the ceiling mount bracket on to the t rail WatchGuard AP330 Hardware Guide 8 WatchGuard Technologies Inc ...

Page 14: ...ting holes 110mm apart 2 Drill the two mounting holes 8 1mm diameter and 26mm depth and hammer the anchors into the holes 3 Screw the anchors into the holes until they are flush with the wall then screw the included screws into the anchors 4 Attach the access point to the wall with the mounting screws WatchGuard Technologies Inc 9 ...

Page 15: ...s For ease of use you can also affix the access point to a wall with the T rail 15 16 mount attached Use the included spacers to place between the mounting screws and the anchors WatchGuard AP330 Hardware Guide 10 WatchGuard Technologies Inc ...

Page 16: ...of the Ethernet cable from your network into the LAN PoE port on the bottom panel of the AP Make sure the other end of the Ethernet cable is connected to your network through a hub switch or injector with PoE 802 3at power enabled WatchGuard Technologies Inc 11 ...

Page 17: ... Input Voltage Rating 100 240V 50 60Hz Output Voltage DC 12V 2 5A Region Specific Adapter Plugs US UK AU NZ EMEA all included Temperature Operating 0 40 C 32 104 F Storage 20 85 C 4 185 F Humidity Operating 5 95 Storage 0 95 Dimensions 69 mm x 32 6 mm x 49 5 mm 2 7 x 1 28 x 1 5 WatchGuard AP330 Hardware Guide 12 WatchGuard Technologies Inc ...

Page 18: ...Injector into an AC power source 2 Connect an Ethernet cable from your network backbone for example a PoE capable router switch or hub to the LAN connector on the Ethernet Power Injector 3 Connect an Ethernet cable from the LAN1 PoE Ethernet interface on the AP to the PoE connector on the Ethernet Power Injector The table provides the specifications for the power adapter Ethernet Power Injector Sp...

Page 19: ...r 10 100 1000 Mbps data and power Voltage Pin4 5 54V Pin7 8 Return Indicator Power Green Temperature Operating 0 40 C 32 104 F Storage 30 80 C 22 176 F Humidity 5 90 Operating and storage Dimensions L 99 mm 3 9 W 68 5 mm 2 27 H 33 mm 1 3 Weight 149 6 g 0 33 lbs WatchGuard AP330 Hardware Guide 14 WatchGuard Technologies Inc ...

Page 20: ...e information regarding approved power sources please contact WatchGuard Technologies FCC Certification This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been teste...

Page 21: ...ust accept any interference received including interference that may cause undesired operation Le présent appareil est conforme aux CNR d ISED applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 le dispositif ne doit pas produire de brouillage préjudiciable et 2 ce dispositif doit accepter tout brouillage reçu y compris un brouillage susc...

Page 22: ...perated with minimum distance 24cm between the radiator your body Déclaration d exposition aux radiations Cet équipement est conforme aux limites d exposition aux rayonnements ISED établies pour un environnement non contrôlé Cet équipement doit être installé et utilisé avec un minimum de 24cm de distance entre la source de rayonnement et votre corps Dynamic Frequency Selection DFS for devices oper...

Page 23: ...n equipment operating in the 2 4GHz ISM band and using wide band modulation techniques Harmonized EN covering the essential requirements of article 3 2 of the RED Directive EN 301 893 V2 1 1 Broadband Radio Access Networks BRAN 5GHz high performance RLAN Harmonized EN covering the essential requirements of article 3 2 of the RED Directive EN 301 489 1 V2 2 3 Electromagnetic compatibility and Radio...

Page 24: ...ng up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 2483 5 MHz For detailed information the end user should contact the national spectrum authority in France WatchGuard Technologies Inc 19 ...

Page 25: ... を目的と し ていますが こ の装置がラ ジオやテレビ ジョ ン受信機に近接して使用さ れると 受信障害を 引き起こ すこ と があり ます 取扱説明書に従っ て正しい取り 扱いをして下さ い VCCI B Taiwan NCC Statement 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更頻率 加大功 率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低 功率射頻器材須忍受合法通信或工業 科學及醫療用電波輻射性電機設備之干擾 1 使用此產品時應避免影響附近雷達系統之操作 本產品電磁波曝露量 MPE 標準值1mW cm2 送測產品實測值為0 347 mW cm2 建議使用時至少 距離人體24cm RoHS Statem...

Page 26: ...on Evaluation Authorization and restriction of Chemicals came into effect on June 1 2007 REACH is Europe s new chemicals legislation which is applicable in all 27 EU Member States as well as the EFTA European Economic Area EEA REACH creates a new system for gathering information assessing risks to human health and the environment and authorizing or restricting the marketing and use of chemicals pr...

Page 27: ...WatchGuard Technologies Inc 22 ...

Reviews: