WATANABE WPMZ-3 Series Quick Instruction Manual Download Page 3

 

 

MODEL WPMZ-3-□□□-□□-□□□                                                                                  

 

3/12 

 

                                                                                                                                                                                                               

IM-0881-04 

4-5-3

 

RS-232C   

*Screwless connector

 

 
 
 
 
 
 

●WPMZ-3-□□□-4□-□□□ 

No. 

Name 

Description 

28 

RXD 

receive data terminal 

29 

TXD 

transmit data terminal 

30 

SG 

common terminal for communication function 

31 to 34 

NC 

no connection 
*Non-usable for a relay terminal 

 
 
 
 

4-5-4

 

RS-485

 

Modbus RTU   

*Screwless connector

 

 

 

 

 

 

 
 
 
 

●WPMZ-3-□□□-5□-□□□ 

No. 

Name 

Description 

28 

 

Non-inverting signal 

29 

 

Inverting signal 

30 

SG 

Signal ground 

31 

 

Non-inverting signal 

32 

 

Inverting signal 

33,34 

TERM 

Terminal resistance 

120Ω

terminals 

* Short 33 and 34 to be enable the resistance. 

5. 

 

NAMES OF EACH PART

5-1. 

 

NAMES OF EACH PART

 

           

 

No. 

Name 

Function 

  Display title  Indicates contents of display 

  Comparison 

result 

Lights when the result of comparative output is 

ON. 

  Compare 

reset 

Lights when the function of compare reset is ON. 

  Key lock 

Lights when the key lock is effective. 

  Pattern 

Indicates pattern No. in use. 

  FUNC key 

Used for registering shortcut function.. 

  MENU key  Used for moving to setting display and returning 

to measurement display. 

  Arrow keys 

Used to move the cursor and to move to other 

displays while setting mode. 

*Shortcut  function  is executed  by  holding  down 
the key over 1 second in measurement display. 

  ENTER key  Used to validate setting value. 

  DISP key 

Used to switch measurement displays. 

  Display unit  Unit for displayed item 

 

Hold type 

Indicate hold type with icon. 
*

 

In addition, 1ch product shows abbreviation 

below. 
HOLD :    DispHold 
MAX 

:   

PeakHold 

MIN 

:   

BottomHold 

PtoP 

:   

AmpHold 

DIFF 

:  

DiffelenceHold 

AVE 

:   

AveHold 

Hold mode 

Indicate hold mode with icon. 
*

 

In addition, 1ch product shows abbreviation 

below. 
NORM

: 

NormalHold 

AREA

: 

  AreaHold 

  3rd item 

Displays measured value of 3rd item 

  2nd item 

Displays measured value of 2nd item 

  1st item 

Displays measured value of 1st item 

  “st” icon 

Indicates the measured value is stable 

  “DZ” icon 

Indicates the operation status of the   
“ Digital zero” function 

  “TZ” icon 

Indicates the operation status of the   
“ Tracking zero” function 

  Comparison 

result 

Lights when the result of comparative output is 

ON. 

  Judgement 

value 

Shows value or area of comparison judgement 

5-2. 

 

EXPLANATION OF ICONS 

5-2-1

 

ICONS FOR EXTERNAL CONTROL 

These are icons when external control is ON. 

Icon 

Meaning 

 

Light when CompareReset function is ON. 

 

Light when DispHold function is ON. 

 

Light when PeakHold function is ON. 

 

Light when BottomHold function is ON. 

 

Light when AmpHold function is ON. 

 

Light when DifferenceHold function is ON. 

 

Light when AveHold function is ON. 

 

Lights when HoldMode is NormalHold. 

 

Lights when HoldMode is ArealHold. 

 

Lights when DispHoldMode is OneShot. 

 

Indicates the operation status of the   
“ Digital zero” function. 

 

Indicates pattern No. in use. 

 

Indicates key lock function is effective. 

 

5-2-2

 

Key Operation Icons on The Setting Display 

 

Icon 

Meaning 

Icon 

Meaning 

 

MENU key 

 

ARROW key

LEFT

 

 

FUNC key 

 

ARROW key

RIGHT

 

 

ENTER key 

 

ARROW key

UP&DOWN

 

 

DISP key 

 

ARROW key

LEFT&RIGHT

 

 

ARROW key

UP

 

 

ARROW key

ALL

 

 

ARROW key

DOWN

 

 

Pattern No. under 
setting 

R

X

D

T

X

D

S

G

N

C

N

C

N

C

N

C

34

28 29 30 31 32 33

Suitable wire:AWG24 to 16

RS-485

T

E

R

M

T

E

R

M

S

G

RS-485

34

28 29 30 31 32 33

*   、  &  、 :connected internally

28 31

29 32

Suitable wire:AWG24 to 16

Summary of Contents for WPMZ-3 Series

Page 1: ...RTU Input Ach Input Bch GO output GO output 2 Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same d...

Page 2: ...ocess input Suitable wire AWG 24 to 16 GO OUT GO GND V HI LO EXC EXC A HI 20 14 15 16 17 18 19 27 21 22 23 24 25 26 connected internally connected internally 22 25 Process input GO output Ach Bch No N...

Page 3: ...iffelenceHold AVE AveHold Hold mode Indicate hold mode with icon In addition 1ch product shows abbreviation below NORM NormalHold AREA AreaHold 3rd item Displays measured value of 3rd item 2nd item Di...

Page 4: ...ve 32 None 2 4 8 16 32 64times Set moving average of input Offset 0 Go to screen of setting offset Only process input Fullscale 10000 Go to screen of setting fullscale Only process input ManuAdjust 0...

Page 5: ...V 10V 1 5V 0 20mA 4 20mA Select a type of output range OutputDispValue None None Ach Bch Calc Select a ch referenced for analog output OutputScale 0 10000 0 99999 100 99999 Scaling of analog output Se...

Page 6: ...lear Erase all alarm log 1st Layer 2nd Layer 3rd Layer setting items 4th Layer setting values Remarks Initial values Initial values 1 Input Wave Compare A Wave Compare B PatternSelect Pattern in use P...

Page 7: ...r DispValue manually that you want to display Back to one before by press left arrow key Go to Fullscale display Near 100 calibration Operation is same as Settings are saved by pressing MENU key and b...

Page 8: ...threshold value to judge How to set the value is shown below The following is an explanation for the compare mode of Level judgement Setting 2 Output CompareAL1 Threshold Set value with arrow keys Pre...

Page 9: ...and performs same action of DISP key TREND LOG FUNCTION Trend log function is to acquire the alarm log any time by external control It is a function to execute with While data is being acquired the tr...

Page 10: ...System Initialize UserDefaultSave 1 Setting each values Set all setting values which are needed as user default values 2 Saving user initial values By executing to save user default values current set...

Page 11: ...etween Power terminals and inputs external controls comparative outputs other outputs AC1500V for 1 minute AC power and DC power Between input terminals and external controls comparative outputs other...

Page 12: ...upper limit or lower limit value AL3 Display value AL4 upper limit or lower limit value AL4 Difference judgement mode When the maximum minimum during the fixed time exceeds the judgement value alarm...