WATANABE WPMZ-3 Series Quick Instruction Manual Download Page 11

 

 

MODEL WPMZ-3-□□□-□□-□□□                                                                                 

 

11/12 

 

                                                                                                                                                                                                               

IM-0881-04 

19. 

 

SPECIFICATIONS 

MODEL CODES

 

WPMZ

S

e

rie

n

am

e

WPMZ-3

P

o

w

e

r

In

pu

t A

c

h

In

pu

t B

c

h

O

u

tp

u

t

C

o

m

pe

ra

tiv

e

 

o

u

tp

u

t

D

e

sc

rip

tio

n

Voltage power:AC100 to 240V

Voltage power:DC12V

S

A

dd

itio

n

al 

c

o

de

T

e

st

 r

e

po

rt

Straingauge measurement

Voltage powerDC24 to 48V

Straingauge input

Test report: No test report

Test report: With test report

00 Stardard (Initial languae: Japanese)

Opencollector output(NPN)

RS-485(Modbus RTU)

S

Straingauge input

Analog output

Display only (No output)

No Bch input

RS-232C

BCD output (Opencollector NPN)

BCD output (Opencollector PNP)

Opencollector output(PNP)

B

Process input

R

Relay output(Normally open)

B

Process input

E0 Initial language setting: English

 

BASIC SPECIFICATIONS

 

Number of 
input channel 

  1 or 2 

According to model codes

 

Display 

  2.4 inch TFT liquid crystal display 

Used in 1ch input 

  Ach measurement result 

Used in 2ch inputs 

  Ach measurement result, 

Bch measurement result, calculation result, Ach and 
Bch measurement results, Ach or Bch measurement 
result and calculation result 

Over warning 

  By exceeding the range of display, displays OVER or 

-OVER 

External controls 

  5  functions  of  the  followings  can  be  assigned  to 

control terminals (user-configurable). 

Comparative output reset function 

Hold reset function A/B/A&B 

Display value holding function A/B/A&B 

Maximum value holding function A/B/A&B 

Minimum value holding function A/B/A&B 

Amplitude value holding function A/B/A&B 

Deviation value holding function A/B/A&B 

Average value holding function A/B/A&B 

Digital zero function A/B/A&B 

Monitor change function 

Trend rog function 

Pattern select function 1/2/3   

Wave compare function A/B 

Multi hold function A/B 

As follows, only short cut setting 

ManuAdjust function A/B 

AutoAdjust function A/B 

Ambient 
temperature range 

  -5 to 50°C 

  

35 to 85%RH

Non condensing

 

Storage 
temperature range 

  -10 to 70°C up to 60%RH 

Supply power 

  AC power

WPMZ-3-1**-**-***

 

AC100 to 240V±10%

 

  50/60Hz 

DC power

WPMZ-3-3**-**-***

 

DC12V±10% 

DC power

WPMZ-3-4**-**-***

 

DC24 to 48V±10% 

Power consumption 

  AC power

WPMZ-3-1**-**-***

 

At AC100V

1

1

VA max

 

At AC240V

1

5

VA max 

DC power

WPMZ-3-3**-**-***

 

At DC12V

6

.5

W max, 

DC power

WPMZ-3-4**-**-***

 

At DC24V

6

.5

W max,

 

At DC48V

:7

W max 

External 
dimension’s 

  96mm

W

×52mm

H

×145mm

D

 

Weight 

  Approx. 350g 

Withstand voltage 
 
 

  AC power 

WPMZ-3-1**-**-***

 

Between  Power  terminals  and  inputs/external 
controls/comparative 

outputs/other 

outputs 

AC3000V for 1 minute 

 

 

DC power 

WPMZ-3-3or4**-**-***

 

Between Power terminals and inputs/external 
controls/comparative outputs/other outputs 
AC1500V for 1 minute 

AC power and DC power 

Between input terminals and external 
controls/comparative outputs/other outputs

 

AC1500V for 1 minute 

Between enclosures and each terminals

 

AC3000V for 1 minute 

Insulation 
resistance 

  Between terminals mentioned above, at DC500V 

100MΩ or higher 

Vibration tolerance 

  10 to 55Hz half amplitude 0.15mm in X, Y, Z 

directions for 30 minutes 

Protective structure 

  IP66

front

 

Installation 
environment 

  indoor use 

Rated altitude 

  up to 2000m 

Transient 
overvoltage 

 

 

Measurement 
category 

 

 

Pollution degree 

  2 

Conformed EN 
standard 

  EN61326-1

EMS

industrial electromagnetic 

environment

EMI

Class A) 

(Applicable to line length only under 30m) 
EN61010-1 
EN50581 

Material of 
enclosure 

  polycarbonate

PC

) 

black UL94V-0 

INPUT SPECIFICATIONS

 

Straingauge input

 

●Input specifications

  (

Common to Ach and Bch) 

Conversion method 

 

∑conversion method 

Applicable bridge 
resistance 

  350Ω 

Bridge voltage 

  DC5V±10% 60mA   

*Four 350 Ω load cells can be connected 
DC10V±10% 30mA 
DC2.5V±10% 30mA 
*When used in combination with process input, 
please use up to 1.2 W in combination with the 
power consumption of the sensor power supply. 

Temperature 
characteristic 

  100ppm/°C 

Input signal 

  Single ended 

Sampling rate 

  Max. 4000 times/sec (1ch product)

 

Max. 2000 times/sec (2ch product) 

Display updating 
period 

  10 sps/ 1 sps 

Zero display 

  Reading zero suppress 

Decimal point 

  Settable freely 

Display resolution 

 

1/99999 

Display range 

  -99999

99999 

Process input

 

●Input specification

 

(Common to Ach, Bch

 

Measurement 

range 

Input 

resistance 

Maximum 

allowable input 

Accuracy 

±5V 

Approx. 

1MΩ 

±100V 

±(0.05

  of FS+1digit) 

 

(at 23±5°C 35

85

RH) 

0

5V 

1

5V 

±10V 

0

10V 

±20mA 

Approx. 

10Ω 

±50mA 

0

20mA 

4

20mA 

*It is possible to measure up to ± 10% FS range on each range.  (Limited 
with ± 10% FS by internal processing. ) 

 

In the bipolar input setting, the full scale is set to be ± separately, and 
for ± 10 V input, for example, limit processing is performed up to ± 11 V. 
(20 V is not treated as FS.) 

 

Also  in  the  accuracy  of  ±  10  V  input,  it  is  prescribed  as  one  side  FS 
handling and accuracy is calculated as 5 mV (0.05%) ± 1 digit. 

Conversion 
method 

 

∑conversion method 

Input signal 
 

  Single ended 

Sampling rate 

  Max. 4000 times/sec (1ch product)

   

Max. 2000 times /sec (2ch product) 

Display updating 
period 

  10 sps/ 1 sps 

Zero display 

  Reading zero suppress 

Bridge 

power 

supply 

Adjustment 

range of gain 

Measurement 

range 

Calibration 

accuracy 

(at 23±5°C   

35~85

RH) 

Nonlinearity 

(at 23±5°C     

35~85

RH) 

5V 

 

1mV/V~ 

3.5mV/V 

-3.5mV/V~ 

3.5mV/V 

±(0.1

  of 

FS+1digit) 

±(0.02

  of 

FS+1digit) 

10V 

2.5V 

Summary of Contents for WPMZ-3 Series

Page 1: ...RTU Input Ach Input Bch GO output GO output 2 Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same d...

Page 2: ...ocess input Suitable wire AWG 24 to 16 GO OUT GO GND V HI LO EXC EXC A HI 20 14 15 16 17 18 19 27 21 22 23 24 25 26 connected internally connected internally 22 25 Process input GO output Ach Bch No N...

Page 3: ...iffelenceHold AVE AveHold Hold mode Indicate hold mode with icon In addition 1ch product shows abbreviation below NORM NormalHold AREA AreaHold 3rd item Displays measured value of 3rd item 2nd item Di...

Page 4: ...ve 32 None 2 4 8 16 32 64times Set moving average of input Offset 0 Go to screen of setting offset Only process input Fullscale 10000 Go to screen of setting fullscale Only process input ManuAdjust 0...

Page 5: ...V 10V 1 5V 0 20mA 4 20mA Select a type of output range OutputDispValue None None Ach Bch Calc Select a ch referenced for analog output OutputScale 0 10000 0 99999 100 99999 Scaling of analog output Se...

Page 6: ...lear Erase all alarm log 1st Layer 2nd Layer 3rd Layer setting items 4th Layer setting values Remarks Initial values Initial values 1 Input Wave Compare A Wave Compare B PatternSelect Pattern in use P...

Page 7: ...r DispValue manually that you want to display Back to one before by press left arrow key Go to Fullscale display Near 100 calibration Operation is same as Settings are saved by pressing MENU key and b...

Page 8: ...threshold value to judge How to set the value is shown below The following is an explanation for the compare mode of Level judgement Setting 2 Output CompareAL1 Threshold Set value with arrow keys Pre...

Page 9: ...and performs same action of DISP key TREND LOG FUNCTION Trend log function is to acquire the alarm log any time by external control It is a function to execute with While data is being acquired the tr...

Page 10: ...System Initialize UserDefaultSave 1 Setting each values Set all setting values which are needed as user default values 2 Saving user initial values By executing to save user default values current set...

Page 11: ...etween Power terminals and inputs external controls comparative outputs other outputs AC1500V for 1 minute AC power and DC power Between input terminals and external controls comparative outputs other...

Page 12: ...upper limit or lower limit value AL3 Display value AL4 upper limit or lower limit value AL4 Difference judgement mode When the maximum minimum during the fixed time exceeds the judgement value alarm...

Reviews: