Preheating temperature / Standby temperature
Defines the target temperature once the main switch has been activated. The pre-heat
temperature also applies to waiting times and rest periods. Default:
85 °C
If the program temperature selected is higher, the temperature reverts back to
this value when the program ends.
After defining the desired working mode , it may make sense to adjust the pre-heat
temperature of the program temperature. This avoids long heat-up or cool-down phases.
The pre-heat temperature may be up to 8 °C higher than the program temperature for the
program to start. The control system will then adjust (reduce) the temperature to the
programmed value.
Clock timer
This defines the weekday activation and deactivation times.
Ongoing programs have a higher priority; they are not switched off until complete.
“Forward in menu”
Display of the sleep mode
By touching the sleep symbol the unit changes into the sleep mode.
15
7
8
10
14
9
Summary of Contents for Wapo-Ex 12 II
Page 1: ...Boil Out Unit Wapo Ex 12 II USER MANUAL...
Page 36: ......