THERE IS AN OIL LEAKAGE HAZARD! It is recommended to change the engine oil at 
the end of the season. That will extend the engine service life. 

  
   Engine oil change 
 

It is recommended to change the engine 
oil after use of this equipment 

(according to 

the Maintenance Schedule)

Switch the engine off. Let 

the  device  cool  down  for  a  while,  so  its  temperature 
drops below 50°C. This will prevent potential burns. The 

engine should remain warm still. 

Warm oil drains 

from the engine more easily. 

 
- Unscrew the OIL PLUG WITH GAUGE. 
- Place a container with the minimum capacity of 1 litre 
below the drain plug.  
- Loosen the drain plug carefully. 
- Let the oil drain smoothly into the prepared container.  
- Once the oil stopped draining, tip the engine to the side 

slightly to let the remaining oil out too. 
- Clean the surroundings of the drain plug and re-tighten the drain plug in its place again.  

    Used  engine  oil  needs  to  be  deposited  at  one  of  the  authorised  collection  points. 

Engine  oil  is 

hazardous waste! 

 
 
 
 Fill the engine with the correct amount and type of engine 
oil. For engine oil specifications, see below.  
- For specific filling volumes refer to the Technical data 
section. 

Set the pump on a horizontal surface.  

Fill  the  engine  with  approximately 

¾

 

of  the  oil  amount 

required.  Screw  the  plug  back  into  the  oil  sump.  With  the 
engine  operation  switch  in  the 

OFF  (0)

  position,  cycle  the 

engine by pulling the starter cord. Remove the plug, wipe the 
gauge dry and check the engine oil level. 

CAUTION:

 To get the correct reading, the gauge must be 

fully screwed in place. Top up the oil to achieve the final level 
between the MIN and MAX marks. 

 

 
 

  Engine oil specifications 
 
Engine oil is one of the factors influencing the performance and service life of 
the engine. 

The minimum requirements for engine oil are:  Viscous grade  10W30 or 10W40 with the quality rating of SF or 
higher (SG, SH, SJ). 
Use  of  engine  oil  grade 

10W30

 

at  ambient  temperatures  exceeding

 

27°C

 

may  result  in  higher  oil 

consumption. The engine oil level therefore requires more attention, when operating the device at such ambient 
temperatures using the engine oil grade

 

10W30

. It is recommended to use oil grade 

10W40 with the quality 

rating

 of

 

SF or higher (SG, SH, SJ).  

The engine oil included in the delivery exceeds the minimum quality requirements highly and it will ensure safe 
operation of the engine with minimum wear of their internal components under demanding operating conditions. 

When topping up the engine oil, use the type and brand of oil already matching the 
existing filling. Mixing of different oil types is not recommended! 
          

Summary of Contents for GF120

Page 1: ...Operation Manual EN GF120 Engine driven Translation of the original operation manual The picture serves for reference only and it may not represent an exact match of the device delivered...

Page 2: ...posed to direct splashing of contaminated water with solid particles With sufficient amount of water in water tank about 20L minimum Environmental protection The packaging materials are recyclable Pac...

Page 3: ...l prior to use of the device For further important information see the section ENGINE p 3 Scope of delivery For depiction of delivery contents see the packaging or the purchase order Check the content...

Page 4: ...iness vomiting or even death The device may be used outdoors only with proper ventilation ensured It is also necessary to prevent ingress of exhaust gases into enclosed rooms via unsealed openings Whe...

Page 5: ...nition spark plug electrode Fuel pipeline check There may be rare cases when the protective metal guards come loose during operation These parts need to be tightened since long term exposure of a loos...

Page 6: ...surface Fill the engine with approximately of the oil amount required Screw the plug back into the oil sump With the engine operation switch in the OFF 0 position cycle the engine by pulling the star...

Page 7: ...essurised water jet on a sample where the potential alteration of surface texture has no impact on the operability or appearance of the particular object Setting the jet further from the surface of ob...

Page 8: ...ump without water or when it s dry causes permanent damage to the pump and voids the warranty Check the water inlet before each use Due to optimum lubrication the pump must be at a maximum incline of...

Page 9: ...fails to generate sufficient water pressure the water jet is intermittent and the water flow is low 1 Nozzle with a large opening used 2 Blocked water supply 3 Low volume of water supply 4 Clogged sc...

Page 10: ...defects of material or workmanship To claim the warranty please submit the sales receipt for your device at your distributor or the closest authorised servicing workshop For the list of approved servi...

Page 11: ...S certificate number Acoustic level measured Lwa Acoustic level guaranteed Lwa GF120 xx0001001 xx9999999 5568 3 2019 03 108 dB 110 dB Test report date Certificate issued by TECHNICK IN PEKCIA a s the...

Page 12: ...customer is obliged to mail the damaged device to the manufacturer s address The device must be complete including accessories and packed properly to prevent its damage during transport it must be fr...

Page 13: ...NECESSARY TO REPLACE THE PLUG FOR BLACK VENT PLUG A WITH EXTENSION Figure A shows the pump vent plug that must be screwed onto the red transport plug located on the top of the pump housing figure B T...

Page 14: ...13...

Reviews: