  Hazard levels 

 

    

DANGER - 

Indication of an immediate danger potentially resulting in serious injuries or death. 

 

 

 

CAUTION - 

Indication of a potential hazardous situation that may result in light injuries.

 

 

  

WARNING - 

Indication of a potential hazardous situation that may result in material damage.

 

 

  Safety features

 

 

  

CAUTION - 

Safety features are designed to protect their users from injuries and these may not be altered 

in any way or even put out of order

Any damaged items must be replaced with original spare parts only. 

 

  Protective guards on hot or rotating parts

                         

 

 

The protective guards are designed for protection of operators using the high-pressure washer to avoid injuries 
caused by temperatures of certain components of the combustion engine or injuries caused by rotating parts of 
the device. 
 
  Safety features on the combustion engine and pump 
 
The engine oil level safety switch (if fitted) serves for automatic deactivation of the engine in case the engine oil 
level drops below the minimum threshold. That will prevent damage to the engine due to insufficient lubrication 
of internal parts. However, this safety features does not substitute the need to check the engine oil level prior to 
use of the device.  
For further important information see the section – ENGINE (p. 3). 
 

 

  

Scope of delivery

 

 

For depiction of delivery contents see the packaging or the purchase order. Check the contents completeness 
when unpacking. Any items missing or any damages incurred in transport should be notified to the seller. 
 

  Additional items required 
 

Source of clean water to fill water tank.  
 
 

  

Assembly

 

 
The device itself is assembled in the manufacturing plant. Before connecting the hoses, remove the covers 
from the high-pressure water outlet and inlet on the pump. The first operation requires connection of the high-
pressure hose, included in the delivery, with the control gun and nozzle to the high-pressure section of the 
pump.  
The next step requires filling of the supplied oil into the engine, as directed by instructions in the section 

ENGINE

 (p. 3) and filling the tank with fresh petrol with octane rating of 95.

              

  

Commissioning

 

 

  Water supply 
 

CAUTION 

Avoid  operating  the  pump  without  a  water  in  water  tank.  Minimum  20L  of  water  is  required  for 

engine start.  If the purity of supplied water cannot be guaranteed, the system needs a water filter placed before 
the pump inlet to avoid influx of solid contaminants inside the pump. 

If  the  pump  has  not  developed  pressure  within  30  seconds  following  its 
commissioning,  switch  the  engine  off  and  proceed  in  compliance  with  instructions 

Summary of Contents for GF120

Page 1: ...Operation Manual EN GF120 Engine driven Translation of the original operation manual The picture serves for reference only and it may not represent an exact match of the device delivered...

Page 2: ...posed to direct splashing of contaminated water with solid particles With sufficient amount of water in water tank about 20L minimum Environmental protection The packaging materials are recyclable Pac...

Page 3: ...l prior to use of the device For further important information see the section ENGINE p 3 Scope of delivery For depiction of delivery contents see the packaging or the purchase order Check the content...

Page 4: ...iness vomiting or even death The device may be used outdoors only with proper ventilation ensured It is also necessary to prevent ingress of exhaust gases into enclosed rooms via unsealed openings Whe...

Page 5: ...nition spark plug electrode Fuel pipeline check There may be rare cases when the protective metal guards come loose during operation These parts need to be tightened since long term exposure of a loos...

Page 6: ...surface Fill the engine with approximately of the oil amount required Screw the plug back into the oil sump With the engine operation switch in the OFF 0 position cycle the engine by pulling the star...

Page 7: ...essurised water jet on a sample where the potential alteration of surface texture has no impact on the operability or appearance of the particular object Setting the jet further from the surface of ob...

Page 8: ...ump without water or when it s dry causes permanent damage to the pump and voids the warranty Check the water inlet before each use Due to optimum lubrication the pump must be at a maximum incline of...

Page 9: ...fails to generate sufficient water pressure the water jet is intermittent and the water flow is low 1 Nozzle with a large opening used 2 Blocked water supply 3 Low volume of water supply 4 Clogged sc...

Page 10: ...defects of material or workmanship To claim the warranty please submit the sales receipt for your device at your distributor or the closest authorised servicing workshop For the list of approved servi...

Page 11: ...S certificate number Acoustic level measured Lwa Acoustic level guaranteed Lwa GF120 xx0001001 xx9999999 5568 3 2019 03 108 dB 110 dB Test report date Certificate issued by TECHNICK IN PEKCIA a s the...

Page 12: ...customer is obliged to mail the damaged device to the manufacturer s address The device must be complete including accessories and packed properly to prevent its damage during transport it must be fr...

Page 13: ...NECESSARY TO REPLACE THE PLUG FOR BLACK VENT PLUG A WITH EXTENSION Figure A shows the pump vent plug that must be screwed onto the red transport plug located on the top of the pump housing figure B T...