Operation Manual
EN
GF120
Engine driven
Translation of the original operation manual
*The picture serves for reference only and it may not represent an exact match of the device delivered
Page 1: ...Operation Manual EN GF120 Engine driven Translation of the original operation manual The picture serves for reference only and it may not represent an exact match of the device delivered...
Page 2: ...posed to direct splashing of contaminated water with solid particles With sufficient amount of water in water tank about 20L minimum Environmental protection The packaging materials are recyclable Pac...
Page 3: ...l prior to use of the device For further important information see the section ENGINE p 3 Scope of delivery For depiction of delivery contents see the packaging or the purchase order Check the content...
Page 4: ...iness vomiting or even death The device may be used outdoors only with proper ventilation ensured It is also necessary to prevent ingress of exhaust gases into enclosed rooms via unsealed openings Whe...
Page 5: ...nition spark plug electrode Fuel pipeline check There may be rare cases when the protective metal guards come loose during operation These parts need to be tightened since long term exposure of a loos...
Page 6: ...surface Fill the engine with approximately of the oil amount required Screw the plug back into the oil sump With the engine operation switch in the OFF 0 position cycle the engine by pulling the star...
Page 7: ...essurised water jet on a sample where the potential alteration of surface texture has no impact on the operability or appearance of the particular object Setting the jet further from the surface of ob...
Page 8: ...ump without water or when it s dry causes permanent damage to the pump and voids the warranty Check the water inlet before each use Due to optimum lubrication the pump must be at a maximum incline of...
Page 9: ...fails to generate sufficient water pressure the water jet is intermittent and the water flow is low 1 Nozzle with a large opening used 2 Blocked water supply 3 Low volume of water supply 4 Clogged sc...
Page 10: ...defects of material or workmanship To claim the warranty please submit the sales receipt for your device at your distributor or the closest authorised servicing workshop For the list of approved servi...
Page 11: ...S certificate number Acoustic level measured Lwa Acoustic level guaranteed Lwa GF120 xx0001001 xx9999999 5568 3 2019 03 108 dB 110 dB Test report date Certificate issued by TECHNICK IN PEKCIA a s the...
Page 12: ...customer is obliged to mail the damaged device to the manufacturer s address The device must be complete including accessories and packed properly to prevent its damage during transport it must be fr...
Page 13: ...NECESSARY TO REPLACE THE PLUG FOR BLACK VENT PLUG A WITH EXTENSION Figure A shows the pump vent plug that must be screwed onto the red transport plug located on the top of the pump housing figure B T...
Page 14: ...13...