background image

BLUE/WHITE 2V (-) LED output: Connect this wire to the blue wire of the supplied LED. Connect the RED wire of
the LED to a fused source of (+)12V.

BLACK (-) chassis ground input: Connect this wire to bare metal, preferably with a factory bolt rather than your
own screw (screws tend to either strip or loosen with time).

RED (+)12V constant power input: Before connecting this wire, remove the supplied fuse. Connect to the battery’s
positive terminal or to the (+)12V feed to the dome light circuit.

NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 10A fuse
in the harness for this purpose. This fuse protects the module itself.

This system uses a microprocessor-based Learn Routine

to learn and store transmitters in memory. Up to four

transmitters are retained in memory, even if the security system is disconnected from the vehicle battery.

To enter the Transmitter/Receiver Learn Routine:

1. Power the system up. If the system is already powered up, it must be powered down

before it will enter the Transmitter/Receiver Learn Routine

.

2. Within 5 seconds press 

on the first transmitter. The siren will chirp once.

3. Within 5 seconds press 

on the first transmitter AGAIN. The siren will chirp twice.

4. Within 5 seconds press 

on the first transmitter a THIRD time. The unit will gener-

ate one long chirp.

5. Repeat Steps 2 through 4 for all transmitters that need to be learned. The system can

learn up to four transmitters.

The Transmitter Learn Routine

will automatically be exited if 5 seconds elapse without the unit receiving a trans-

mitter code. The system will generate one short chirp followed by a long chirp when the Learn Routine

is exited.

TRANSMITTER/RECEIVER LEARN ROUTINE™

WIRE CONNECTION GUIDE

4

© 1999 Directed Electronics, Inc.

N718W  7/99

Summary of Contents for 718W

Page 1: ...atus LED 3 Wire Connection Guide 4 Transmitter Receiver Learn Routine 4 To Enter the Transmitter Receiver Learn Routine 4 Operation Settings Learn Routine 4 To Enter the Operation Settings Learn Routi...

Page 2: ...hts after they lose power Disconnecting the battery requires this code to be erased which can require a trip to the dealer Before beginning the installation Remove the domelight fuse This prevents acc...

Page 3: ...unt the unit with the siren facing down This will prevent water damage to the unit Route the wires away from the unit and make sure they are securely fastened away from the moving parts of the engine...

Page 4: ...memory even if the security system is disconnected from the vehicle battery To enter the Transmitter Receiver Learn Routine 1 Power the system up If the system is already powered up it must be powered...

Page 5: ...d 5 Program the selected feature Pressing Button I on the transmitter will select the one chirp setting and the siren will chirp once Pressing Button II on the transmitter will select the two chirp se...

Page 6: ...result the unit may have better range with Code Hopping off The system features a Doubleguard shock sensor inside the control unit All adjustments to the sensor are made using the transmitter To adjus...

Page 7: ...n I to decrease the sensitivity or Button II to increase the sensitivity Each time Button I is pressed the unit will emit one chirp and the sensitivity is decreased one step Each time Button II is pre...

Page 8: ...sor performance If relocation of the control unit does not improve performance of the sensor the angle of the unit and the bracket may be changed as shown below Remember the siren must be protected ag...

Reviews: