- 46 -
6.5
Sensor
This option is used to calibrate the selected sensor. We recommend calibrate the sensor before
printing when changing the media.
Auto
Calibration
Gap
Black Mark
Continuous
Gap
Menu
Sensor
Manual Setup
Threshold
Detect
Maximum
Length
Advanced
Black Mark
Continuous
Auto
Fixed
Item
Description
Default
Auto Calibration
Printer will feed 2 to 3 gap labels to calibrate the sensor sensitivity
automatically.
N/A
Manual Setup
In case “Auto calibration” cannot apply to the media, please use
“Manual setup” function to calibrate the sensor sensitivity.
N/A
Threshold Detect
This option is used to set sensor sensitivity in fixed or auto.
Auto
Maximum Length
This option is used to set the maximum length for label
calibration.
254mm
Advanced
This function can set the minimum paper length and maximum
gap/bline length for auto-calibrate the sensor sensitivity.
OFF