Rinse Thermostat
Part Number
30201
Function
Controls the rinse element
Description
The rinse thermostat is a single pole capillary type device. It has a single changeover contact
and a rotating shaft for a manual temperature adjustment.
Factory default setting is 85°C.
Contact switching capacity: 16(4) A 380 V.
Diagram
Replacement
Take note of the connections to the wiring loom before disconnecting. Move the capillary
bulb out of the thermostat pocket inside the rinse tank. Replace in reverse order.
Adjustment
Remove the capillary bulb of the temperature gauge out of the rinse tank pocket and insert
the probe of a digital thermometer into that pocket. Check the thermostat settings on a
temperature rise. Adjustment is performed by rotating the adjustment shaft of the
thermostat. Clockwise rotation of the shaft increases the setting, anticlockwise– decreases it.
Re-fit the temperature gauge capillary bulb into the rinse tank pocket.