User manual

5

1 Safety Precautions

• Servicing shall be carried out only by authorized personnel.
• Only authorized spare parts, accessories and consumables shall be used.
• The machine is not to be used if industrial chemicals have been used for cleaning.
• Do not dry unwashed items in the machine.
• Items that have been soiled with substances such as cooking oil, acetone, alcohol, pet-

rol, kerosene, spot removers, turpentine, waxes and wax removers should be washed
in hot water with an extra amount of detergent before being dried in the machine.

• Items such as foam rubber (latex foam), shower caps, waterproof textiles, rubber

backed articles and clothes or pillows fitted with foam rubber pads should not be dried
in the machine.

• Fabric softeners or similar products should be used as specified by the fabric softener

instructions.

• The final part of a drying cycle occurs without heat (cool down cycle) to ensure that the

items are left at a temperature that ensures that the items will not be damaged.

• Remove all objects from pockets such as lighters and matches.
• WARNING. Never stop the machine before the end of the drying cycle unless all items

are quickly removed and spread out so that the heat is dissipated.

• Adequate ventilation has to be provided to avoid the back flow of gases into the room

for appliances burning other fuels, including open fires.

• Exhaust air must not be discharged into a flue which is used for exhausting fumes from

appliances burning gas or other fuels.

• The machine must not be installed behind a lockable door, a sliding door or a door with

a hinge on the opposite side to that of the machine in such a way that a full opening of
the machine is restricted.

• If the machine has a lint trap this has to be cleaned frequently.
• The lint must not be accumulated around the machine.
• DO NOT MODIFY THIS APPLIANCE.
• When performing service or replacing parts, the power must be disconnected.
• When the power is disconnected, the operator must see that the machine is discon-

nected (that the plug is removed and remains removed) from any point to which he has
access. If this is not possible, due to the construction or installation of the machine, a
disconnection with a locking system in the isolated position shall be provided.

• In accordance with the wiring rules: mount a multi-pole switch prior to the machine to

facilitate installation and service operations.

• WARNING: The appliance must not be supplied through an external switching device,

such as a timer, or connected to a circuit that is regularly switched on and off by a utility.

• If different rated voltages or different rated frequencies (separated by a /) are stated at

the machine data plate, instructions for adjusting the appliance for operation at the re-
quired rated voltage or rated frequency are stated in the installation manual.

• Stationary appliances not fitted with means for disconnection from the supply mains

having a contact separation in all poles that provide full disconnection under overvolt-
age category III, the instructions state that means for disconnection must be incorpo-
rated in the fixed wiring in accordance with the wiring rules.

• The openings in the base, shall not be obstructed by a carpet.

Summary of Contents for D7-550

Page 1: ...User manual Tumble dryer D7 550 Type N2 Original instructions 438921563 EN 2023 03 01...

Page 2: ......

Page 3: ...How to start the machine 13 3 3 Additional functions 14 3 4 When program has ended 15 4 Error codes 16 5 Maintenance 17 5 1 General 17 5 2 Time for maintenance 17 5 3 Every day 17 5 4 Machines with r...

Page 4: ......

Page 5: ...ot be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machine h...

Page 6: ...g countries AT BE BG HR CY CZ DK EE FI FR DE GR HU IS IE IT LV LT LU MT NL NO PL PT RO SK SI ES SE CH TR UK The appliance can be used in public areas This appliance can be used by children aged from 8...

Page 7: ...f doubt the installer shall contact the supplier The appliance should be installed on non flammable materials for the floor worktop and or wall close to the appliance if required If you can smell gas...

Page 8: ...to the range of use to which the machine is intended different markets use different programs The following program description is a short description of some exam ples of programs that can be used F...

Page 9: ...en the preset or selected time has ended During a drying cycle when the square in the lower right corner is fully ticked it indicates that the heating unit is ac tive ON The heating unit can be gas el...

Page 10: ...or example man made fiber textiles like polyester polyamide natural fiber textiles silk textiles WOOL Normal temperature The program will stop before the garments are totally dry which protects the ga...

Page 11: ...can be selected The program will stop when the time is up AIRING DRIES SET TIME Without heat Different drying times can be selected The program will stop when the time is up Programs with NORMAL TEMP...

Page 12: ...e there are no metal objects such as screws pins etc left Metal objects might cause damage to the drum Load the goods into the machine according to recommendations and close the door Make sure the fil...

Page 13: ...essing the up and down buttons Button Example of programs NORMAL LOW NO HEATING Start the machine by pressing the start button After start it is possible to change the time for the selected program Pu...

Page 14: ...active on your machine Pause It is possible to pause an ongoing program Select PAUSE and activate For some machines it is also possible to pause directly when pressing the start button When pressing...

Page 15: ...s important to empty the machine as soon as the program has ended If the machine is not emptied as soon as the program has ended the drum will rotate in short intervals in order to keep the goods from...

Page 16: ...code text disappears On Coin operated machines Reset by pressing the service button 12 15 NO VACUUM The machine is overfilled or the garment is too wet Unload some of the garment and try to start agai...

Page 17: ...available a telephone number and or a tag will also be displayed The machine can be used meanwhile However the message will keep coming back until the service is performed The message will disappear...

Page 18: ...is can result in more moist load than requested at program end 5 5 Maintenance to be carried out by qualified service personnel Contact qualified service personnel to perform the following maintenance...

Page 19: ...d and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but mu...

Page 20: ...Electrolux Professional AB 341 80 Ljungby Sweden Share more of our thinking at www wascomat com...