Fig 7-5
Example of system oil tank arrangement (DAAE007020e)
Design data:
see Technical data
Oil tank volume
75...80% of tank volume
Oil level at service
60% of tank volume
Oil level alarm
7.3.3
Gravity tank (2T02)
In installations without engine driven pump it is required to have a lubricating oil gravity tank,
to ensure some lubrication during the time it takes for the engine to stop rotating in a blackout
situation.
The required height of the tank is about 7 meters above the crankshaft. A minimum pressure
of 50 kPa (0.5 bar) must be measured at the inlet to the engine.
Tank volume [m
3
]
Engine type
1.0
6L46F
2.0
7L46F, 8L46F, 9L46F, 12V46F
Wärtsilä 46F Product Guide - a19 - 1 December 2017
7-9
7. Lubricating Oil System