DE
IMO Tier 2
ME
IMO Tier 2
Wärtsilä 9L46F
1200
1200
kW
Cylinder output
600
600
rpm
Engine speed
10.0
10.0
Nm
3
Consumption per start at 20°C, (with slowturn)
Notes:
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Flow tolerance 5%.
Note
1
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C). Flow tolerance 5% and temperature tolerance
15°C.
Note
2
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Tolerance for cooling water heat
10%, tolerance for radiation heat 30%. Fouling factors and a margin to be taken into account when dimensioning heat ex-
changers.
Note
3
According to ISO 15550, lower calorific value 42700 kJ/kg, with engine driven pumps (two cooling water + one lubricating
oil pumps). Tolerance 5%. The fuel consumption at 85 % load is guaranteed and the values at other loads are given for in-
dication only.
Note
4
At manual starting the consumption may be 2...3 times lower.
Note
5
ME = Engine driving propeller, variable speed
DE = Engine driving generator
Subject to revision without notice.
Wärtsilä 46F Product Guide - a19 - 1 December 2017
3-13
3. Technical Data
Wärtsilä 46F Product Guide
Summary of Contents for 12V46F
Page 1: ...PRODUCT GUIDE Wärtsilä 46F ...
Page 44: ...This page intentionally left blank ...
Page 52: ...This page intentionally left blank ...
Page 78: ...This page intentionally left blank ...
Page 102: ...This page intentionally left blank ...
Page 124: ...This page intentionally left blank ...
Page 144: ...This page intentionally left blank ...
Page 162: ...This page intentionally left blank ...
Page 186: ...This page intentionally left blank ...
Page 192: ...This page intentionally left blank ...
Page 194: ...This page intentionally left blank ...
Page 197: ......
Page 198: ......
Page 199: ......