3. 

Description of the UPS-system 

 
3.1      Preface 
  

We wish to congratulate you on the good bargain of the UPS JOVYLINE

.

 The static UPS chosen from you 

contains the latest findings on power electronic and digital control logic. The JOVYLINE offers a cost-
effective decent solution of problems in power supply of electronic data processing equipment. 
 
You can connect devices out of this series to computer platforms via the standardised interface RS232. 
A respective software for the supervision of important functions is enclosed to the UPS. 
 
Our JOVYLINE UPS-system are UPS-systems of type VFD directly fed by the mains. As a standard the AVR 
is component part of our systems. AVR means: automatic voltage control, i.e. even in case of power supply 
through the mains the output voltage at the output socket is constant within separate voltage steps. 
Please take the values out of table 1 on page 4 of this manual. 
 
Production of these UPS-systems is subjected to a strict quality control. 
 
The JOVYLINE UPS offers an optimal solution of problems as we give special emphasis to the highest 
reliability of our systems. That’s guaranteed by our whole organisation and our experiences in power supply 
technology for more than 50. 
 

Remark! In some special cases, in some special installations it’s possible that the UPS in spite of its 
radio-screening interferes delicate devices. In that case it’s no mistake of the UPS. You have to 
extend the distance between the fed device and the UPS. Remove aerials located quite near the UPS. 
 
The UPS has to be power supplied through a separate socket.

 

 

 

In case of technical questions or in case of disturbances you can dial our service department by the following 
phone numbers: 
 
 
 

Customer service: 

 

+49 491 - 6002 - 30

 

 
Service Fax: 

 

 

+49 491 - 6002 - 10

  

 
Email:    

[email protected]

 

 
Internet-Homepage:  

http://www.jovyatlas.de 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for Jovyline 1200

Page 1: ...BAX 3522 E Operating Manual UPS Systems W rtsil JOVYLINE 625 1200 2200...

Page 2: ...before installation Pay attention to each special hint within the separate chapters to avoid later disturbances of the device right from the start In case of problems please contact our Service depart...

Page 3: ...625 1200 2200 7 4 Installation 11 5 Operation of the UPS system 12 6 Alarms 13 7 Software options 13 8 Computer interface connection 14 9 Replacing of batteries 14 10 Troubleshooting 15 _____________...

Page 4: ...itches off immediately or input protection gets released Input protection Protection against overload and short circuit Type of battery Lead battery closed maintenance poor 12V 7Ah JOVYLINE 625 24V 7A...

Page 5: ...s bracelets etc at your arms and hands which could lead to a short circuit at the poles of the battery A short circuit on the battery can produce a very high short circuit current which leads usually...

Page 6: ...ltage at the output socket is constant within separate voltage steps Please take the values out of table 1 on page 4 of this manual Production of these UPS systems is subjected to a strict quality con...

Page 7: ...in its capacity the LED lightens up You have to replace the battery 2 Battery feeds load yellow LED If the load is fed by the battery the yellow LED lightens up 3 Mains OK green LED If the input volta...

Page 8: ...ns the standardised RS 232 interface and works under the operation systems Novell Unix DOS Windows and others 6 Output sockets 7 Mains input socket with mains fuse 8 Socket for telephone modem with sp...

Page 9: ...value The load is fed with normal voltage 3 Battery feeds load yellow LED If the battery feeds the load the yellow LED lightens up 4 AVR automatic voltage regulation yellow LED The LED lightens up if...

Page 10: ...protection against voltage transients for modem network and telephone offers a completely safe internet connection 6 USV Port For communication between UPS and Computer 7 Output sockets Normal Versio...

Page 11: ...PC with the RS232 interface by the cable enclosed 4 4 Connection of external battery blocks optional Before connection of the battery block secure that the battery plug and the connection cable are c...

Page 12: ...UPS You can use the self test of the UPS to get a statement of the UPS function and battery function To start the self test you have to push the push button ON OFF during normal operation of the UPS i...

Page 13: ...o remove parts of the load or replace the UPS by a bigger one Even consumers with a high peak current absorption such as laser printer plotter or faxes lead to an overload of the UPS Therefore it s ad...

Page 14: ...nd burns 5 Place the new batteries in the same position as the old ones Connect the battery wiring to the battery again red wiring black wiring 6 Screw on the cap of the cabinet 7 Follow the instructi...

Reviews: