BATTERY CHARGER
16
。
F
alse defect note
When
the battery is inserted into the charger and the status LED blinks RED, remove the
battery from the charger for 1 minute, then reinsert. If the status LED blinks GREEN, then
the battery is properly charging. If the status LED is still blinking RED, remove the battery
and unplug the charger for 1 minute.
After 1 minute, plug in the charger and reinsert the battery. If the status LED blinks
GREEN, then the battery is properly charging. If the status LED is still blinking RED, the
battery is defective and needs to be replaced.
CHECKING THE CHARGE
I
f the battery pack does not charge properly:
• Check the current at the power outlet with another tool. Make sure that the outlet is not turned
off.
• Check that the charger contacts have not been shorted by debris or foreign material.
• If the air temperature is above 104
°
F or below 45
°
F, move the charger and battery pack to a
room temperature location.
CHARGER MOUNTING
(See Figure 14.)
1.
This charger can be installed hanging on a wall using two #8 screws (not included).
2.
Locate the placement for the charger to be wall mounted.
3.
If fastening to wood studs use 2 wood screws (not included).
4.
Drill two holes on center 5.5 in. apart ensuring that they are vertically aligned.
5.
If fastening to drywall use wall anchors (not included) and screws to secure the charger to the
wall.
Note: If the battery and the charger won
’t be used for a long time, remove the battery from the charger and pull out the
AC power plug.
Fig.14