WPE DIESEL GENERATORS
FEATURES
3
EN
FEATURES
WPE Diesel generator possesses the following features:
This series diesel generator adopts super-light type, air
cooled, 4-stoke direct injection diesel engine and has two
starting options:
1. Recoil start
2. Electric start.
They are equipped with large capacity fuel tank, circuit
protector, A.C and sometimes D.C voltage outputs, low oil
pressure alarm and automatic stopping device.
The diesel generator serves as an UPS stand-by power
supply in many different applications including open
working site, construction and field army. Emergency
power of poultry farm, fishery, forestry, garden, hotel,
shop, and office.
This operation manual tells you how to operate and
service your new diesel generator. Please read it before
using the diesel generator to ensure proper handing
and operation. Following these instructions carefully will
keep your diesel generator in the best working condition,
allowing to prolong the life of your diesel generator.
If you have any questions concerning your new product
or any of the information given in this manual, please
contact 44(0)1942 715 407.
PARAMETERS
The generators can generate specified power when used
in the following conditions:
Altitude: < 1000m
Ambient Temperature: 5 to 40°C
Relative humidity: <90%
WARNING
Exhaust/mufflers and gases are very hot to
touch. DO NOT add or install any exhaust/muffler
extensions, by doing so you will void any warranty
offered.
Preventing burns
NEVER touch or handle exhaust/muffler, engine when
generator is running or hot, always leave approx 30
minutes for the exhaust/muffler & engine to cool before
handling.
IMPORTANT
Please read and understand this operation manual to
insure safe operation, and pay high attention to the
following main points of operation otherwise it may
cause personal injury and damage to equipment.
Preventing fires
The fuel of diesel engine is light diesel fuel , so gasoline,
kerosene etc. must NEVER be used.
Wipe away all fuel spills with a clean cloth. Keep
gasoline, kerosene, matches and other explosives
and inflammable substance away from the generator,
because the temperature around the exhaust muffler is
very high during operation. To prevent fire hazards and
to provide adequate ventilation, keep the generator at
least 1.5 meter away from buildings, structures and other
equipment during operation.
Operate the generator on a flat level surface, there may
be fuel spillage or poor operation if the generator is tilted.
Preventing exhaust gas inhalation
Exhaust gas contains poisonous carbon monoxide.
Always use the generator in outdoor locations minimum
1.5m anyway from window, doors or opening.
Generators MUST never be used indoors, in garages,
cabins, out building, sheds or any confined spaces
including vehicles and vehicle compartments.
Electric shocks, short circuits
In order to avoid electric shocks or short circuit, do not
touch the generator, when either it or your hands are wet.
This generator is not waterproof , so it should NEVER be
used in a place exposed to rain, snow or water sprays.
The generator should be ground to prevent electric
shocks. Please connect a length of heavy wire between
the generator’s ground terminal and an external ground
device, ground rod or stake - minimum 200mm deep.
Do not connect any equipment to the generator before
you start it.
WARNING
Most appliance motors require more than their rated
wattage for start up. Do not exceeded the current
limit specified for any one socket.
Charging the battery
Battery electrolyte contains sulphuric acid. Protect
your eyes, skin and clothing. In case of contact, flush
thoroughly with water and get prompt attention,
especially if your eyes are affected.
Batteries generate hydrogen gas, which can flames or
sparks near a battery, especially during charging.
Charge the battery in a fully ventilated area.