background image

-8- 

 

 

 

 

 

 

20w 40 

10w 40 

      

      

    

      

 

 

 

    

      

    

7. Maintenance and Remedy of Generator Set 

Notice: Proper maintenance is not only the basis of safe, economical and easy 

way of generator operation, but also helpful to reduce the air pollution. 

Warning: If the maintenance instructions are not followed properly, it may cause 

serious personal injury. 

Maintenance Schedule 

 

Maintain period 

 

Item month 
working hours

 

 

 

Every 

time use

 

 

The  first 
month or 
20 hours

 

 

Every three 
months  or 
100 hours

 

 

Every three 
months  or 
100 hours

 

 

Oil

 

Check

 

 

 

 

 

 

Renew

   

 

 

(First time)

 

 

 

(Second time)

 

 

Air cleaner 

element

 

Check

 

 

 

 

 

 

Clean

   

 

 

 

 

The valve gap

 

Check- 
adjust

 

 

 

 

 

 

The liquid of 

the battery

 

Check

 

 

 

 

 

 

 

Oil filter

 

Clean

   

 

 

 

 

Renew

   

 

 

 

 

Fuel filter

 

Renew

   

 

 

 

 

Fuel pipe

 

Check

 

Every two years or necessary to renew

 

 

Recommend oil 

4 stroke diesel engine oil, API CE, CF 
the same as the CG (SAE10W-30) oil. 

 

S A E 

 

10w 

20w 

20 

30 

40 

 

-30    -20      -10     0 

10      20 

30     40 (C 

A.P.I diesel engine maintenance classification 

20 

40 

60      80 

100(F 

Oil should be CE or over CE standard 

Recommend number 
Can use range 

 

 

Summary of Contents for LDG12S

Page 1: ...WARRIOR GENERATORS USER MANUAL FOR MODELS LDG12S LDG12S3...

Page 2: ...Before Start DG12 Check Before Operation 5 DG12S Check Before Operation 6 5 Operation 7 6 Stopping Generator 7 7 Maintenance DG12 Check and Maintenance DG12S Check and Maintenance 9 10 8 Appendix and...

Page 3: ...tion while the generator set is shut down and isolated Diesel Fuel is combustible and can ignite Do not overfill the fuel tank fill to recommended level on gauge Make sure the fuel cap is tightly secu...

Page 4: ...Brushless AC single phase Brush AC three phase Frequency Hz 50 60 Voltage V 110 115 120 220 230 240 110 220 115 230 120 240 220 380 230 400 110 115 120 220 230 240 110 220 115 230 120 240 220 380 230...

Page 5: ...on Quantity 1 Top cover 1 2 Frame 1 3 Engine side cover 1 4 Front cover 1 5 Muffler assy 1 6 Air cleaner assy 1 7 Engine 1 8 Shock absorber 6 9 Lock wheel 2 10 Alternator 1 11 Wheel 2 12 Control panel...

Page 6: ...1 7 Rubbe rcover 1 8 Alternator clapboard 1 9 Alternator 1 10 Muffler heat insulation cover 1 11 Muffler assy 1 12 Engine 1 Item Description Quantity 13 Muffler assy 1 14 Shock absorber 6 15 Battery 1...

Page 7: ...s lower limit when take out the ways of adding oil as below 7 1 Finally install and plug oil gauge Notice DO NOT run generator with low oil level or below Minimum this will cause generator engine part...

Page 8: ...r engine parts to damage 2 Fuel level Caution Please refuel in a well ventilated area make sure there is NO cigarettes naked flames or sparks when refuel Open left door check the fuel level indicator...

Page 9: ...esn t start please wait for about 30 seconds OFF ON before attempting to start again 3 AC application In accordance with the actual situation to connect the load through the load terminals or wiring s...

Page 10: ...e The first month or 20 hours Every three months or 100 hours Every three months or 100 hours Oil Check Renew First time Second time Air cleaner element Check Clean The valve gap Check adjust The liqu...

Page 11: ...rain plug back Open the lock over the front cover 4 1 screw the cylinder head oil cap 2 as the photo pull the oil until reach the oil gauge max limited 4 1 in the end screw back the cylinder head stud...

Page 12: ...lace drain plug back Move the plastic rounded lid on the top of genset unscrew the cylinder head oil cap fill the oil until reach the oil gauge max limited 4 1 in the end screw back the cylinder head...

Page 13: ...storage 2 Storage instructions Do not touch the muffler Around the exhaust port of the muffler is very hot while generator is running and the heat will remain for some time after generator stops To pr...

Page 14: ...n or rings in wrong place Change and adjust piston ring Valve clearance is not correct Adjust the clearance as per operational manual Bolts of cylinder head are not tight Re tight the bolt Check fuel...

Page 15: ...13 10 Electrical Wiring Diagram Single Phase Generator 11 Electrical Wiring Diagram Three Phase Generator...

Reviews: