background image

tsa2mdl5sm-rev0315

sandpiperpump

.

com

Model TSA2 • 

6

Recommended Installation Guide

Troubleshooting Guide

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

Symptom:

Potential Cause(s):

Recommendation(s):

Pump Cycles Once

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Air valve or intermediate gaskets installed incorrectly. Install gaskets with holes properly aligned.
Bent or missing actuator plunger.

Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate 

/ Cycle

Pump is over lubricated.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Lack of air (line size, PSI, CFM).

Check the air line size and length, compressor capacity (HP vs. cfm required).

Check air distribution system.

Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators. 

Discharge line is blocked or clogged manifolds.

Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Blocked air exhaust muffler.

Remove muffler screen, clean or de-ice, and re-install. 

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump chamber is blocked.

Disassemble and inspect wetted chambers. Remove or flush any obstructions. 

Pump Cycles and Will 

Not Prime or No Flow

Cavitation on suction side.

Check suction condition (move pump closer to product).

Check valve obstructed. Valve ball(s) not seating 

properly or sticking.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.  

Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. 

Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or 

manifold).

Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical 

 

Resistance Guide for compatibility.

Valve ball(s) / seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.
Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump Cycles Running 

 

Sluggish / Stalling,

 

Flow Unsatisfactory

Over lubrication.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Icing.

Remove muffler screen, de-ice, and re-install. Install a point of use air drier. 

Clogged manifolds.

Clean manifolds to allow proper air flow.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Cavitation on suction side.

Check suction (move pump closer to product).

Lack of air (line size, PSI, CFM).

Check the air line size, length, compressor capacity.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Air supply pressure or volume exceeds system hd.

Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling. 

Undersized suction line.

Meet or exceed pump connections. 

Restrictive or undersized air line.

Install a larger air line and connection. 

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary.

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous. 

Product Leaking 

Through Exhaust

Diaphragm failure, or diaphragm plates loose.

Replace diaphragms, check for damage and ensure diaphragm plates are tight.

Diaphragm stretched around center hole or bolt holes. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility 

with products, cleaners, temperature limitations and lubrication.

Premature Diaphragm 

Failure

Cavitation.

Enlarge pipe diameter on suction side of pump.

Excessive flooded suction pressure.

Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure. 

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.

Misapplication (chemical/physical incompatibility).

Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations 

and lubrication.

Incorrect diaphragm plates or plates on backwards, 

installed incorrectly or worn.

Check Operating Manual to check for correct part and installation. Ensure outer plates have not been 

worn to a sharp edge.

Unbalanced Cycling 

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Undersized suction line.

Meet or exceed pump connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. 

UNIVERSAL ALL SANDPIPER, EXCEPT FLAP

2: INST

AL

 & OP

Summary of Contents for Sandpiper TSA2

Page 1: ...ld Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Certified ISO 14001 Certified SERVICE OPERATIN...

Page 2: ...en loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonmetallic pumps and plastic components are not UV stabilized Ultraviolet radiation can damage t...

Page 3: ...nstallation Guide Troubleshooting Guide SECTION 3 EXPLODED VIEW 7 Composite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 10 Air Distribution Valve Assembly Pilot V...

Page 4: ...el Wetted Aluminum Air Pump Series TS SANDPIPER Pump Design A Flap Pump Size 2 2 1 2 Sanitary Tri Clamp Discharge Porting Position D Bottom Your Serial fill in from pump nameplate ____________________...

Page 5: ...ess Steel Equal to or exceeding ASTM specification A743 CF 8M for corrosion resistant iron chromium iron chromium nickel and nickel based alloy castings for general applications Commonly referred to a...

Page 6: ...81 249 3 50 89 11 76 299 2 1 2 SANITARY TRI CLAMP SUCTION PORT AIR INLET 13 56 345 25 6 2 69 68 20 13 511 3 32 84 17 89 454 3 31 84 2 57 65 2 1 2 SANITARY TRI CLAMP DISCHARGE PORT 16 00 406 13 00 330...

Page 7: ...eck valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pulle...

Page 8: ...ation The air distribution system is designed to operate WITHOUT lubrication This is the standard mode of operation If lubrication is desired install an air line lubricator set to deliver one drop of...

Page 9: ...of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed...

Page 10: ...gs Plunger Actuator Seal U Cup 476 040 366 Wet End Kit FDA White Nitrile Diaphragms Flap Valve Gaskets Seat Flange Hinge Pad Sealing Ring Spacer 1 3 2 6 48 49 12 26 27 11 46 44 22 46 16 21 16 13 46 25...

Page 11: ...196 002 110 NS Chamber Outer 2 20 286 007 366 Diaphragm FDA White Nitrile 2 21 312 012 110 P Elbow Suction Prod 2 22 312 013 110 Elbow Discharge 2 23 338 005 366 Flap Valve White 4 24 360 011 366 Gas...

Page 12: ...uctive Nitrile 408 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506 Delrin 150 520 Injection...

Page 13: ...mmendations stated in this manual will damage the pump and void factory warranty Air Distribution Valve Servicing See repair parts drawing remove screws Step 1 Remove Hex Head Cap Screws 5 Step 2 Remo...

Page 14: ...s 1 3 E 560 023 360 O Ring Spool 2 3 F 675 037 080 Retaining Ring 1 3 A 3 F 3 D 3 B 3 C 3 E Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 3 F Step 2 Remove sleeve 3...

Page 15: ...water is recommended No lubrication is required Step 4 Push the threaded outer diaphragm plate through the center hole of the diaphragm Note Most diaphragms are installed with the natural bulge out t...

Page 16: ...andard EN809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchas...

Reviews: