  INTIG 401 PULSE

 

 

 

  DC Pulse Argon Welding Machine

Front panel

5.1.1 Digital display area:

A. A.A.1st digital display meter: it is used to display welding/preset current,

pulse/AC frequency, pulse width ratio/clean width, pre-gas time etc.

B. B.B.Display type indicator of 1st digital display meter: when the 1st digital

display meter is displaying welding current, this indicator is on.

C. C.C.2nd digital display meter: it is used to display welding voltage, pass

no. etc.

D. D.Display type indicator of 2nd digital display meter: when the 2nd digital

display meter is displaying voltage, this indicator is on

5.1.2 Selection and adjusting area of parameters:

- 8 -

A

B

C

D

Summary of Contents for INTIG 401

Page 1: ...B1 1604 INTIG 401 PULSE DC Pulse Argon Arc Welding Machine OPERATOR S MANUAL PLEASE READ CAREFELLY BEFORE OPERATION...

Page 2: ...g machine is 35 there is protection function when the machine is overloading used When it s protected and no power output must wait and after the temperature back to normal then use again 5 When weldi...

Page 3: ...the same time when using of degreasing cleaning or spraying operations The heat and rays of the arc can react with these gases to form phosgene a highly toxic gas Some protective gases used in weldin...

Page 4: ...tromagnetic Welding current going though any area can generate electromagnetic as well as the welding equipment itself Electromagnetic would affect cardiac pacemaker the cardiac pacemaker users should...

Page 5: ...iew 5 2 Working condition and environment 5 3 Specification and parameters 5 4 System description 6 5 Structure description 7 6 Installation 12 7 Operation 13 8 Maintenance 13 9 Trouble shooting 14 10...

Page 6: ...pieces except magnesium aluminum alloy such as stainless steel pipeline boiler aerospace equipment etc 2 Working condition Environment 2 1 Input Power 2 1 1 The exact input voltage wave shape should b...

Page 7: ...nt Rage A 0 120 Gas Pre flow Time S 0 5 Arc Striking Current Range A 5 400 5 500 Current Up slope Time S 0 10 Welding current A 5 400 5 500 Pulse Peak Current Range A 5 400 5 500 Pulse Background Curr...

Page 8: ...e width The negative feedback signal which is the real welding current get from the output current sensor put into the special PWM circuit after compared with the current adjust signal then output the...

Page 9: ...etc B B B Display type indicator of 1st digital display meter when the 1st digital display meter is displaying welding current this indicator is on C C C 2nd digital display meter it is used to displ...

Page 10: ...Welding current it is the current when there is no pulse working F Arc force current the arc force current of MMA G Hot start current the hot start current of MMA H Rotary encoder it is used to adjust...

Page 11: ...g welding torch it should be air cooling position when use water cooling welding torch it should be water cooling position and start the water pressure checking function 5 1 4 Operation mode area A Tw...

Page 12: ...el It quits the channel if there is no action within 5 seconds B Storage key to store the present welding parameter to the present channel C Parameter selection key to select a stored parameter to use...

Page 13: ...l signal connector D Communication interface B to connect the remote controller E Name plate position F Serial number position G Remote controller installation position H Air cooling fan I Air inlet t...

Page 14: ...es not need the cooling water but the water cooling welding torch so only when use water cooling welding torch the water can be connected in 6 4 When work as Tig connect terminal to work piece firmly...

Page 15: ...fter welding please don t take away the welding torch at once should wait the gas post flow time finish to protect the weld crater and tungsten electrode 7 6 MMA connect the work piece too according t...

Page 16: ...switch to auto position The spring in the air valve may have elastic shortage open the air valve and extend the spring 7 No argon The voltage of the air valve coil is insufficient or the coil was burn...

Page 17: ...e 2 Piece 9 Operation manual Qualified certificate Guarantee card 1 Piece 11 Key components list No Name Model Specification 1 Air switch INTIG 401 PULSE DZ47D 3P 40A 40A INTIG 501 PULSE DZ47D 3P 63A...

Page 18: ...V 11 0V TC1 XS3D 37 XS3C 38 XS3B 39 XS3A 0 XS5C XS5D XS5E XS5F 07 08 XS1C 11 XS1A 10 1 5V 1 5V EN D 1 5V 1 5V END NC NC XS7A 62 XS7B 63 XS7E 66 XS7C 64 XS7F 67 XS7D 65 XS2B XS2C XS2F XS2D XS2A XS2E X...

Page 19: ...INTIG 401 PULSE DC Pulse Argon Welding Machine The final explanation rights reserved to our Company If there is any changes in the user s manual forgive not to inform separately 18...