INTIG 316/501 AC/DC
- 13 -
items must be paid attention to:
●The flammable matters must be far away from the welding site.
●Before welding, check if there are flammable matters in the operation range or not, in order to take them
away for eliminating hidden troubles.
6.Installation
1.
Installation location
The location conditions should follow the items below and the distance between the machine and the
wall or the other machines should be at least 30cm.
Keep the machine away from direct sunlight , rain and dusty atmosphere.
The floor must be massive and flat, such as cement floor.
2.
Exterior connection
A fuse breaker or a breaker without fuse must be set at the input side of each welding machine.
Before connecting, the switch OFF the electricity distribution box .
Have the fast connector of earth cable connected to terminal of welding machine, and
the other end of cable is connected to workpiece properly.
Have the fast connector of torch cable connected – terminal, and the gas inlet nut of the torch to
the gas outlet of the machine. The water inlet pipe of the torch connects with the water outlet
connector of the machine; the water outlet pipe of the torch connects with the water backward
of the machine.
Warning: the fast connector must be connected tightly, or else it may produce heat may damage
connector.
Argon flow meter
Argon flow meter is the exclusive flow regulator for argon, which cannot be used for the other
high pressure gas. It is not allowed to disassemble the argon flow meter.
Additionally, it is not allowed to touch the pressure adjusting devices and screws inside the meter.
Otherwise, fatal accidents may happen.
The water inlet mouth of welding machine is connected with the water output mouth of
recycling water cooler, the water-returning mouth of welding machine is connected with
water-returning mouth of recycling water cooler.
Notice:
For this series welding machines,water cooling unit is outside the power source, when
using water cooled torch connect torch as per below diagram . ( picture 4 )