background image

7

ASSEMBLY INSTRUCTIONS (Portable Models)

PH-45-20-P-LP (Liquid Propane) (for use with 20 lb. propane cylinder) 
PH-45-30-P-LP (Liquid Propane)  (for use with 20 lb. & 30 lb. propane cylinders).

Step 1
Carefully remove all packages from the main packing box.  Remove the base assembly 
from the interior packing box. Gently lift the tank cover off of the base assembly and set 
aside.    For shipping purposes, the heater head is bolted in place, inverted, inside the 
assembly.  Gently rotate the heater head “counterclockwise” until it is free.  Discard the 
metal threaded “T” that is holding the head in place.  (See Figure 1)

  Figure 1                                                      Figure 2                             Figure 3

Step 2
Remove the 53” hose from it’s packaging and thread the ½” end into the heater head.  A 
suitably approved pipe thread sealant must be used.  Use 2 pipe wrenches to ensure a 
tight and leak free fit.    Remove the 3/8” x 1” bolt from the base of the heater head 
(Figure 2) and set aside so as not to lose it.  Slide the heater head / hose assembly into the 
3”  post.  The top of the post can be identified by the 3/8” hole being at the top end.  Line 
up the 3/8” hole in the post with the 3/8” hole in the base of the heater head, and replace 
the previously removed 3/8” x 1” bolt.  Tighten securely.

Step 3
Replace the tank cover so that it sits down in place on the weighted base.  Figure 3
Thread flexible hose down through the opening of the post support assembly and stand 
the post in the assembly.  Raise decorative cover to allow access to the tank storage area.

Step 4
Secure the regulator to the end of the flexible hose.  Use a pipe wrench and suitably 
approved gas pipe sealant to ensure a tight and leak free connection.  Secure coupling nut 
on regulator into the tank outlet valve on the propane cylinder (cylinder not included).

Step 5

Secure the reflector dish to top of the heater head assembly using nuts provided

Step 6
Ensure that the heater is used on a secure and level surface, maintaining the clearances to 
combustibles as outlined on page 2 of this manual.

Heater

head

Rotate

counter

clockwise

Post
Support

53”
hose

3” x 53”
post

3/8”

x 1”

bolt

Summary of Contents for Patio Plus

Page 1: ...asy Radiant Works accepts no responsibility for damages whatsoever resulting in improper installation of this heater Improper installation voids all warranties This manual must remain with the heater...

Page 2: ...red to be wood compressed paper plant fibres or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or p...

Page 3: ...osed Patios Enclosed patios must be large enough to meet the clearance to combustibles and ventilation requirements as provided for in all applicable codes For very small enclosed patios Patio Plus he...

Page 4: ...e kept clean 6 WARNING gas leaks are extremely dangerous and potentially explosive Do not use this product until a leak is repaired Easy Testing Procedure 1 Prepare a cup of soapy water 2 Attach regul...

Page 5: ...ing options PH 45 H LP Liquid Propane PH 50 H N Natural Gas Hanging Units PH 45 H R LP Liquid Propane PH 50 H R N Natural Gas Hanging Units with 24 volt remote switching option PH 45 IG LP Liquid Prop...

Page 6: ...heater and be sure to check all connections each time the cylinder is connected Always turn off the gas supply to the heater at the cylinder as soon as you are finished using the heater The L P cylin...

Page 7: ...the heater head hose assembly into the 3 post The top of the post can be identified by the 3 8 hole being at the top end Line up the 3 8 hole in the post with the 3 8 hole in the base of the heater he...

Page 8: ...ide the decorative cover onto the post from the bottom Place the post into the basemount T on the weighted base and slide the decorative cover down over the post retainer Connect gas supply to nipple...

Page 9: ...t Aline the 3 8 hole in the post with the 3 8 threaded hole in the base of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Slide the decorative cover onto the post from the bottom P...

Page 10: ...se of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Insert post into the ground support pipe and fasten with hardware provided Connect the gas supply to the nipple protruding from...

Page 11: ...ess cannot be created on the gas supply piping Step 3 Apply a suitably approved pipe sealant to the nipple protruding from the bottom of the hanging bracket Turn the heater head onto the nipple to ach...

Page 12: ...ank or other system After pilot is lit and it is mistakenly turned off the knob will be in an immovable position Wait 90 seconds and the thermocouple will cool and knob will be released to re light pi...

Page 13: ...Defective gas valve Dirty pilot Replace thermopile Replace gas valve Clean pilot Main Burner won t light No 24 Volt power to unit Low gas pressure Blockage in orifice Manual valve not in on position...

Page 14: ...tends a 3 YEAR warranty from the date of purchase to the original purchaser of this product against manufacturing defects in material and workmanship If this product fails to operate because of a manu...

Page 15: ...15...