Important Safety Rules

1. Children and adults should be alert to high surface temperatures of 

areas above the post when operating this heater.

2. Children should be carefully supervised when they are in the area of 

the heater.

3.

NEVER

 hang anything including clothes or other flammable items on 

the heater.

4.

DO NOT

 operate this heater unless it is fully assembled with a 

reflector in place, and on a flat, level stable surface.

5. Installation and repairs must be done by a qualified service person.  A 

qualified gas person should inspect the heater before use and at least 
annually.  More frequent cleaning may be required as necessary.  It is 
imperative that control compartments, burners and circulating air 
passages of the heater be kept clean.

6.

WARNING:

 gas leaks are extremely dangerous and potentially 

explosive!  Do not use this product until a leak is repaired.

Easy Testing Procedure

1. Prepare a cup of soapy water.
2. Attach regulator to your L.P. tank or gas line securely.  Leave the L.P. 

tank outside the cabinet for the testing procedure.

3. Open the valve of the L.P. tank or turn main gas valve to heater “ON”, 

then leave the heater valve in the “OFF” position.  With a brush or 
sponge, apply the soap and water mixtures liberally to all connections 
and fittings.  Any leaks will blow soap bubbles.  Repair any and all 
leaks by tightening or replacing defective fittings.  Once any and all 
leaks have been stopped, the heater is ready for use.

DO NOT USE A FLAME FOR LEAK TESTING

This product must be assembled and tested as shown in these instructions.  
Any deviation or lack of testing could cause personal or property damage.  
Have a qualified professional do it for you.

Summary of Contents for Patio Plus

Page 1: ...asy Radiant Works accepts no responsibility for damages whatsoever resulting in improper installation of this heater Improper installation voids all warranties This manual must remain with the heater...

Page 2: ...red to be wood compressed paper plant fibres or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or p...

Page 3: ...osed Patios Enclosed patios must be large enough to meet the clearance to combustibles and ventilation requirements as provided for in all applicable codes For very small enclosed patios Patio Plus he...

Page 4: ...e kept clean 6 WARNING gas leaks are extremely dangerous and potentially explosive Do not use this product until a leak is repaired Easy Testing Procedure 1 Prepare a cup of soapy water 2 Attach regul...

Page 5: ...ing options PH 45 H LP Liquid Propane PH 50 H N Natural Gas Hanging Units PH 45 H R LP Liquid Propane PH 50 H R N Natural Gas Hanging Units with 24 volt remote switching option PH 45 IG LP Liquid Prop...

Page 6: ...heater and be sure to check all connections each time the cylinder is connected Always turn off the gas supply to the heater at the cylinder as soon as you are finished using the heater The L P cylin...

Page 7: ...the heater head hose assembly into the 3 post The top of the post can be identified by the 3 8 hole being at the top end Line up the 3 8 hole in the post with the 3 8 hole in the base of the heater he...

Page 8: ...ide the decorative cover onto the post from the bottom Place the post into the basemount T on the weighted base and slide the decorative cover down over the post retainer Connect gas supply to nipple...

Page 9: ...t Aline the 3 8 hole in the post with the 3 8 threaded hole in the base of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Slide the decorative cover onto the post from the bottom P...

Page 10: ...se of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Insert post into the ground support pipe and fasten with hardware provided Connect the gas supply to the nipple protruding from...

Page 11: ...ess cannot be created on the gas supply piping Step 3 Apply a suitably approved pipe sealant to the nipple protruding from the bottom of the hanging bracket Turn the heater head onto the nipple to ach...

Page 12: ...ank or other system After pilot is lit and it is mistakenly turned off the knob will be in an immovable position Wait 90 seconds and the thermocouple will cool and knob will be released to re light pi...

Page 13: ...Defective gas valve Dirty pilot Replace thermopile Replace gas valve Clean pilot Main Burner won t light No 24 Volt power to unit Low gas pressure Blockage in orifice Manual valve not in on position...

Page 14: ...tends a 3 YEAR warranty from the date of purchase to the original purchaser of this product against manufacturing defects in material and workmanship If this product fails to operate because of a manu...