8
Warner Electric • 800-825-9050
P-2010-7 • 819-0525
Power and Brake Wiring
24 Volt Systems
Using The Internal 24V Power Supply
o
1.
Wire the positive (+) side of the 24 volt DC
power supply to terminal 10 of the
MCS2000-PSDRV2. Make sure that the
terminal is securely tightened on the
MCS2000-PSDRV2.
o
2.
Wire the negative side (-) or DC common
of the 24 volt DC power supply to terminal
9 of the MCS2000-PSDRV2. Make sure
the terminal is securely tightened on the
MCS2000-PSDRV2.
Using External 24 VDC Power Source
o
1.
Connect the positive side of the 24 VDC
power source to the positive (+) input,
terminal 10. Tighten terminal securely.
o
2.
Connect the negative side of the 24 VDC
power source to the negative (-) input,
terminal 9. Tighten terminal securely.
Note:
Make sure the current capacity is sufficient
to handle the brake load and driver
circuitry. If any other external power
requirements are required, then the power
supply capacity must be sized to handle
these currents as well.
Brake Wiring (Optional AC Power Wiring)
o
1.
Wire the brake for Channel “A” on
terminals 5 and 6 of the MCS2000-
PSDRV2. Make sure the terminals
are securely tightened.
o
2.
If a brake is to be used on Channel “B”
wire the brake to the Channel “B”
terminals 7 and 8 on the MCS2000-
PSDRV2. Make sure the terminals are
securely tightened.
o
3.
Wire AC power; hot neutral, and ground to
the power input terminals on the right side
of the MCS2000-PSDRV2. Make sure
terminals are securely tightened.
Note:
Warner Electric Tension brakes are not
polarity sensitive, so wiring between
terminals on the MCS2000-DRV2 and
brake are not sensitive to the + and -
designations.
The following 24 volt tension brakes can be used
with the MCS2000-DRV2 Driver for 24 volt
operation.
TB Series
ATT Series
MTB Series
Magnetic Particle
TB-170
TB-260
TB-425
TB-500
TB-825
TB-1000
TB-1225
TB-1525
ATTB/ATTC-25
ATTB/ATTC-55
ATTB/ATTC-115
All MTB’s up to 12
magnets
*Up to 16 magnets if
outputs paralleled and
inputs paralleled
MPB/MPC2
MPB/MPC15
MPB/MPC70
MPB/MPC120
MPB240
POB/POC-0.3 to 20’s
PRB-H’s 1.2 to 20’s
PTB’s 2.5 to 20’s
PMC-A’s 10 to 40’s
PHC-R 0.6 to 40’s
*POB/POC-40 & 80 if output
and inputs paralleled
* When 16 magnet MTB Brakes and POB/POC-40 and 80 Magnetic Particle Brakes are used,
inputs and outputs must be wired parallel to obtain sufficient output current for proper brake.