The following chart shows a comparison of the MCS2000-PSDRV, MSC2000-PSDRVH and the
MCS2000-PSDRV2 terminal connections.
LED’s
Green
Green
Red
Red
LED Operation
OFF
OFF
ON
ON
ON
Functional Description
Internal installation error at power up.
Fault Error. Output locked “OFF”,
Driver has tripped.
Return MCS2000-PSDRV2 for Repair.
0.5 Sec ON/0.5 Sec OFF
1.5 Sec ON/0.5 Sec OFF
Short Circuit or Overload on Output at
Power Up. Output Locked “OFF”, Driver
has tripped.
Reset by Power Off and then Power On.
Short Circuit or Overload during normal
operation. Output Locked “OFF”. Driver
has tripped.
Reset by Power Off and then Power On.
Internal auxiliary power supply out of
tolerance. Output Locked “OFF”.
Auto Reset when condition clears.
Internal auxiliary power supply failure or
drive power supply greater than 48 VDC,
+10%. Output Locked “OFF”.
Auto Reset when condition clears.
OR
Figure 7 LED Indicator Operations and Descriptions – Fault Conditions