background image

4

   

Warner Electric • 800-825-9050

P-2104-WE • 819-0548

There are switching options that can be used with 
the CBC-802 clutch/brake control. Determine which 
switching option you will be using and wire the 
switching inputs for that option.

Option 1 – Momentary Push Button 

Switches 

7

8

3

START

STOP

CBC-802

Switches

Normally open

pushbutton.

Momentarily

contact closure

1.  Connect the normally open start switch 

contacts to terminals 7 and 8 of the socket. 
Tighten terminal 8 securely.

2.  Connect the normally open stop switch 

contacts to terminals 7 and 3 of the socket. 
Tighten both terminals securely.

3.  This completes the wiring of the CBC-802. 

Double check all terminal wiring at this time.

 

 

Proceed to the start-up section of this 
manual.

Option 2 - 2-wire Maintained Switching

7

8

3

CBC-802

7

8

3

CBC-802

or

When using option 2 for switching input, the 
switch wiring must be such that in normal state the 
contacts are closed at power-up to insure brake 
output is energized. Switching can be either through 
a maintained type switch or relay contacts as shown 
above.

1.   Connect a jumper wire from terminal 7 to 

terminal 8 of the socket. Tighten terminal 8 
securely.

q

  2.   Connect the normally closed switch or 

normally closed relay contacts to terminal 7 
and terminal 3 of the socket. Tighten both 
terminals securely.

3.   This completes the wiring of the CBC-802. 

Double check all terminal wiring at this time. 

 

 

Proceed to the start-up section of this 
manual.

Option 3 - Solid State Switching – NPN 

Open Collector Logic

8

3

7

CBC-802

Solid

StateSwitches

NPN type open

collector outputs,

or NPN type

transistor with

both collector

and emitter

unterminated

When using solid state 

switching, the emitter or output common of 
the switching device cannot be grounded. If 
the outputs are grounded, then either different 
switching devices must be used or an input 
isolation transformer on the AC input to the 
CBC-802 must be used, or the CBC-802 will be 
destroyed.

q

  1.   Connect the collector of the NPN output 

transistor or switching device to terminal 3 
of the socket for stop input. Tighten terminal 
3 securely.

q

  2.   Connect the collector of the NPN output 

transistor or switching device to terminal 8 
of the socket for start input. Tighten terminal 
8 securely.

q

  3.   Connect the emitter of the NPN output 

transistors or switching device common 
for both stop and start to terminal 7 of the 
socket. Tighten terminal 7 securely.

q

  4.   This completes the wiring of the CBC-802. 

Double check all terminal wiring at this time. 

 

 

Proceed to the start-up section of this 
manual.