WARMTEC T510 Weekly Programming Thermostat with LCD Screen

                                         

Installation Manual

 

WARMTEC T510 Weekly Programming Thermostat with LCD Screen

                                         

Installation Manual

 

 
 

T510. Weekly Programming Thermostat with LCD Screen 

Weekly  circulation,  it  is  possible  to  set  6  periods  called  events  each  day  with 
different  temperatures,  also  you  can  select  "manual  mode"  or  "temporary 
control  mode"  according  to  your  individual  requirements.  The  thermostat  is 
recommended for the control of electric heating devices or on/off valve actuator 
used in water-based heating systems. 
 

Selection Table:

 

Model 

Current 

Application 

T510 

16A 

Built-in  &  floor  sensor,  floor  limit  sensor,  period 

programming 

T510i 

16A 

A pair of contacts for potential- free output 

 
Technical data: 

Voltage                                : AC230V (AC110V/AC24V available) 
Power consumption            : 2W 
Setting range             

     

    : 5

~90

 

Limitation range         

   

    : 5

~99

  (factory setting: 35

Switching differential 

   

    :0.5

~10

  (factory setting:

 

±

1

Ambient temperature          : -5

~50

 

Protective housing              : IP20 
Housing material                : self-extinguishing PC 
 

Daily use of the thermostat

 

1

 

on/off "

2

 

In the manual mode

press "

" or"

"to make temporary control

 

3

 

Press"

" or"

" to increase or decrease pre-set temperature. 

4

 

Press"

"  and"

"and  hold  for  5  seconds  at  the  same  time  to  adjust 

time.  Press  "

"  to  choose  object  to  adjust;  Press"

"  or"

"  to 

increase or decrease your set values; Press "

" to confirm and exit. 

5

 

Press the "

" key to select manual mode or clock-controlled program 

mode. 

6

 

It displays the time or the pre-set temperature alternately, and it displays 
the measured temperature directly. 

7

 

When you press "

" and"

"at the same time and hold for 5 seconds, 

the thermostat will be locked/unlocked. When it is locked, no operation 
can be carried out until it is unlocked. 

 

Display symbols

 

  Manual mode   

  Period control mode                     

 

  Heating                                         

  Getting up, the first period         

  Out in the morning, the second period                             

  Going home at noon, the third period 

  Out in the afternoon, the forth period 

 

Going home in the evening, the fifth period 

   

Sleeping at night, the sixth period 

 
 

Period programming

 

Press "

" and hold for 5s to enter the mode of Period programming. 

Key 

Period 

Symbol 

Time 

 

Temperature

 

 

 

we
ek

d

ay

 

 

06:00 

 

 

 

 

 

 

S

et

 th

st

art
/e

n

d

 ti

me

  
 

20

 

S

et

 p

ro

g

ra

mme

d

 te

m

p

era
tu

re

 

 

08:00 

15

 

 

11:30 

15

 

 

12:30 

15

 

 

17:00 

22

 

 

22:00 

15

 

we
ek

en

d

 

 

08:00 

22

 

 

23:00 

15

 

 

Advanced setting (qualified person preferred) 

When the thermostat is turned off, You can press"

" and turn on it at the same 

time ,then you can enter the mode of advanced setting. 
 

Symbol 

Setting 

                or 

ADJ 

Temperature 
calibration 

Adjust measured temperature 
 

SEN 

Sensor mode 

IN: built-in sensor 
OUT: floor sensor 
ALL: both sensors 

3. 

LIT 

Limitation 
temperature 

Adjust limitation value, 
Limitation range:5

~60

 

DIF 

Switching 
differential 

Adjust switching differential 

LTP 

Antifreeze 
function 

Turn on/off Anti-frozen 
function 

PRG 

Set vacation 
mode 

00: 5/2 day mode 
01: 6/1 day mode 
02: 7 day mode   

RLE 

Potential- free 
output and main 
power output in 
the 
same/different 
way 

Change the present 
linkage way 

DLY 

Delay time of 
Potential- free 
output   

Change linkage delay time 

HIT 

Max temperature 

Limitation temperature 

setpoint 

 

AFAC 

Reset to factory 
settings 

Press"

"and hold for 5s

all 

parameters will be reset   

 
Sensor failure: 

Please  select  the  right  sensor  mode  when  operation,  it  will  display  the 
"Err" symbol on screen far sensor failure, thermostat must be checked till 
the fault is eliminated 
 

Explanation of symbols: 

Period mode

Antifreeze

temperature

Lock key

heating

power

NTC

Decrease key

Increase key

Menu

Week

Time 

Six period

Manual mode

 

Dimension: 

Unit: mm 