1. Humidity control
2. Protective functions
During operation, the device controls the humidity level in the dried room.
- If the minimum humidity value is set on the control panel, the device will go into continuous
dehumidification mode. In this case, use the POWER button to turn off the dehumidification
mode.
- When the unit is turned on, the compressor starts with a 3 second delay, while when turned
off, the fan will run for 3 additional seconds.
- When the desired humidity in the room is reached, the compressor will be turned off and the
fan will run for 1 minute after turning off.
Depending on the settings made on the control panel, the fan and compressor will be started
automatically after switching on until the set humidity value is reached. When the desired
humidity value in the room is reached, the fan and compressor will be turned off.
- If the humidity sensor is damaged, the device will go into continuous dehumidification mode.
In this case, use the POWER button to turn off the dehumidification mode.
Full water tank
- Memory of the last settings: in the event of a sudden power failure or accidental
disconnection of the power plug, when the power is restored, the device will start
automatically with the last settings. The operation of the device will continue until the next
time the device is turned off or the settings are changed manually.
When the water tank is full, the dehumidifier will automatically go into standby mode and the
control panel will display a message and a "full" icon.
- To protect the unit from damage, if the compressor runs continuously for 10 minutes and the
internal sensor (TR) temperature reading is not more than 3 degrees from the exchanger
temperature (TP) for 10 consecutive seconds (i.e. TR-TP ≤ 3 °), read this relationship as a failure
(possible leak or blockage in the pipe), and shut down the dryer immediately.
- When the device is turned on for the first time, the quick start function is activated, and each
time the device is turned off and then turned on again, the compressor will start after about 3
minutes from the moment of starting the device.
31
FUNCTION DESCRIPTION
Summary of Contents for OP-50
Page 1: ...OSUSZACZ POWIETRZA v 1 09 OP 50 50 D DEHUMIDIFIER PL EN...
Page 2: ...2...
Page 24: ...24...
Page 44: ...44 NOTATKI...
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...
Page 48: ...www warmtec pl v 1 09...