background image

6.3

Floor Temperature Limits (AF mode only)

NOTE

: To avoid damaging your floor, follow your floor supplier’s recom-

mendations regarding floor temperature limits.

The minimum and maximum floor temperature limits are 5 °C (41 °F) and
28 °C (82 °F) by default. To modify these limits, proceed as follows:

Switch the thermostat to Standby.

Press and hold the 

 button.

Switch the thermostat back to On.

Release the 

 button when the minimum temperature 

limit (

) appears.

Set the minimum temperature limit using the 

 buttons.

Press the 

 button to display the maximum temperature 

limit (

).

Set the maximum temperature limit using the 

 buttons.

Press 

Mode/Ret

 to exit.

The thermostat has 3 modes of operation.

7.1

 Automatic Mode

The thermostat follows the programmed schedule. To place the ther-

mostat in this mode, press 

Mode/Ret

 until   is displayed. The data of

the current schedule period are also displayed.

Temporary Bypass

If you modify the setpoint temperature (by pressing the 

 or 

button) when the thermostat is in automatic mode, the new tempera-

ture will be used until the beginning of the next period.   flashes dur-
ing the bypass. You can cancel the bypass by pressing 

Mode/Ret

.

Programmed Schedule

The schedule consists of 4 periods per day which represents a typi-
cal week day. You can program the thermostat to skip the periods
that do not apply to your situation. For example, you can skip periods
2 and 3 for the weekend.

The Comfort (

) temperature is used in periods 1 and 3 and the

Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically

changes from Comfort (

) temperature to Economy ( ) temperature.

You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.

To modify the schedule:

Press 

Pgm

 to access the programming mode. Period 1 is 

selected.

Press 

Day

 to select the day to program (hold for 3 seconds to 

select the entire week).

Press 

Hour

 and 

Min

 to set the start time of the selected period, 

or press 

Clear

 if you want to skip the period (--:-- is displayed).

NOTE

: If you intend to use only 2 periods, set periods “1 and 4” 

or periods “2 and 3”. Early Start will not work if you set periods 
“1 and 2” or periods “3 and 4” .

Press 

Pgm

 to select another period, or press 

Day

 to select 

another day. Then repeat step 3.

Press 

Mode/Ret

 to exit the programming mode.

NOTE: 

If no button is pressed for 60 seconds, the thermostat will

automatically exit the programming mode. 

7.2

 Manual Mode

The programmed schedule is not used. The temperature must be set
manually. To place the thermostat in this mode:

Press 

Mode/Ret

 until   is displayed.

Set the temperature using the 

 or   button.

7.3

 Vacation Mode

In this mode, the thermostat is set to Vacation temperature. There
are two ways to place the thermostat in Vacation mode:

By pressing the 

 button on the thermostat. When the Vacation

mode is activated using the 

 button, the 

 icon appears on the

screen without flashing.
From an Aube telephone controller (CT240/CT241) or any other
remote control device equipped with a dry contact if your power
base is equipped with the ECONO input. When the contact

closes, the Vacation mode is activated and the 

 icon flashes on

the screen. All buttons on the thermostat are locked. When the
contact opens, the thermostat returns to the preceding mode.

NOTE

: When the Vacation mode is activated using a remote

control device, it can only be deactivated using the device

.

The measured temperature is below the thermostat’s display
range. Heating is activated.

The measured temperature is above the thermostat’s display
range. Heating is deactivated.

Verify the thermostat and sensor connections.

:

Power supply

: Refer to the power base’s installation guide.

Display range

: 0 °C to 70 °C (32 °F to 158 °F)

Ambient setpoint range (A/AF modes)

: 5 °C to 30 °C (40 °F - 86 °F)

Floor setpoint range (F mode)

: 5 °C to 40 °C (40 °F - 104 °F)

Floor limit range (AF mode)

: 5 °C to 40 °C (40 °F - 104 °F)

Display resolution

: 0.5 °C (1 °F)

Operating temperature

: 0 °C to 50 °C (32 °F to 120 °F)

Storage temperature

: -20 °C to 50 °C (-4 °F to 120 °F)

Heating cycle length

: Refer to the power base’s installation guide

Data backup

: In the event of a power failure, most settings are saved.

Only the time must be re-adjusted if the power failure lasts more than 6
hours. The thermostat will return to the mode that was active prior to the
power failure.

Aube warrants this product, excluding battery, to be free from defects in the work-
manship or materials, under normal use and service, for a period of three (3) years
from the date of purchase by the consumer. If at any time during the warranty
period the product is determined to be defective or malfunctions, Aube shall repair
or replace it (at Aube's option).
If the product is defective,
(i)

return it, with a bill of sale or other dated proof of purchase, to the place from
which you purchased it, or 

(ii)

contact Aube. Aube will make the determination whether the product should
be returned, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall
not apply if it is shown by Aube that the defect or malfunction was caused by dam-
age which occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms
stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD-
UCT. Some provinces, states or regions do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which
vary from province, state or region to another.

For any questions regarding product installation or operation, contact us
at:

705 Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600 
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
E-mail: [email protected]

For more information on our products, visit us at:

www.aubetech.com

Modes of Operation

7.

Period

Description

Associated temperature setting

Wake-up

Away from home

Return home

Sleep

Period

Setting

MO

TU

WE

TH

FR

SA

SU

6:00

6:00

6:00

6:00

6:00

6:00

6:00

8:30

8:30

8:30

8:30

8:30

--:--

--:--

17:00

17:00

17:00

17:00

17:00

--:--

--:--

23:00

23:00

23:00

23:00

23:00

23:00

23:00

Error Messages

8.

Technical Specifications

9.

Warranty

10.

Customer Assistance

11.

24/7 Installation Support  •  Lifetime Technical Assistance  •  Free Design Service  •  www.WarmlyYours.com  •  (800) 875-5285 