15 September 2017

 

 

All Dimension are in mm………….Copyright © 

 

1

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

Warmington Tasman 46L & 70L Fires

 

 

Visit 

www.warmington.co.nz 

for Spec’s, DWG’s and PDF uploads of Fires

 

 

Fire, Flue System and Instructions to Comply with ASNZS 2918:2001

 

 

Keep these Instructions for further reference……Ensure that you have the correct and current Installation details for the Warmington Fire

 

 

Installation

 

The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA SFAIT Installation Technician .

 

See www.warmington.co.nz/members for a Certified NZHHA SFAIT Installer in your area .

 

 

CLEARANCES TO COMBUSTIBLE SURFACES UNLESS STATED

 

 

IMPORTANT 

Read all the instructions carefully before commencing the Installation. Failure to follow these instructions may result in a fire hazard and void the warranty 

Freestanding Fires - Clean Air Approved Wood Burner

 

Installation Instructions

 

ADD Cowl

 

Flashing Cone

 

Galv Combo Liner

 

Ceiling

 

Flue

 

Warmington

 

Double Flue

 

Shield

 

Floor Protector

 

Summary of Contents for Tasman 46L Fire

Page 1: ...ation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA SFAIT Installation Technician See www warmington co n...

Page 2: ...CIENCY BURNING SOFTWOOD 66 Council Authorisation No Ecan 111359 Nelson 111359 When Tested in Accordance with AS NZS 4012 Performance may vary from tested values depending on actual operating condition...

Page 3: ...d for most types of freestanding wood burners Check List Front Steel Baffle Vermiculite Board Baffle Brick Vermiculite Side Bricks X2 Check Door Seal Check Damper Control Serial Number Check Packed By...

Page 4: ...s walls or surfaces Ref to ASNZS 2918 2001 3 2 1 The clearance to a Non Combustible wall or surface can be less that 100mm if a wet back is not fitted and no requirement for maintenance Construction o...

Page 5: ...lite Board baffle brick in first on an angle through the door frame then repeat for the steel baffle Join the two parts together lift it up holding it horizontally resting on the one side bricks Fit b...

Page 6: ...pproximate Note Before using the Fire with a Wet Back Fitted Consult your plumber for wet back system configurations and oper ation Wet back is to be fitted to an internal heat sync before use e g Hot...

Page 7: ...be assembled with crimped ends down towards heater STAGE 7 Place Ceiling Plate over heater flue spigot ensuring the folded edge up stands are facing ceiling STAGE 8 From the roof lower Flue Pipes thr...

Page 8: ...pipe casing Note External Requirements Refer to AS NZS2918 2001 4 9 1 Install Flue system to AS NZS2918 2001 When using a rubber or Bitumen flashing Butynol Dectite an Additional Flue pipe Baffle is...

Page 9: ...oved outdoors immediately to a location clear of combustible materials 4 Cooking Because the top of the fire is in direct contact with the flame it offers a large cooking surface Ideal for entertainme...

Page 10: ...Fire Contact with your local TA Territorial Authority to check for local compliance 11 Flue System The installation and construction of the flue system must comply with ASNZS 2918 The fire requires a...

Page 11: ...mary on Setting High Temp Pain Read Stove Manufacturer instructions Babies small children pregnant women and pets should leave the area during the paint setting phase Ventilate well Paint surface will...

Page 12: ...8 2001 and the appropriate Building codes The Flue system and Fireplace is to be swept annually or more frequently if required The Appliance and Flue System has been tested to ASNZS2918 2001 WARNINGS...