PLAN VIEW OF CLEARANCES TO COMBUSTIBLES
—CORNER & SRAIGHT “Tested to ASNZS : 2918”
BAFFLES & POSITIONING
Situation
1
.
Combustible Surface with stainless steel
reflective Flue Shield*
2.
Non
-
combustible surface including
walls, finishings and framing without
Flue Shield, e.g. Concrete/Block/Brick/
ACC
Re Clearance to a Non Combustible
materials walls
or surfaces Ref to
ASNZS:2918:2001 3.2.1.
The clearance to a Non Combustible
wall or surface can be less that
100mm if a wet back is not fitted and
no requirement for maintenance.
* Construction of Flue Shield must be in
accordance with ASNZS 2918 (minimum
Flue Shield height is 1200mm)
Baffle in Position
Steel Baffle
Vermiculite
Board
Description
46L :1
46L :2
70L :1
70L :2
To Wall Behind
I
150
100
To Wall Side
J
350
100
To Flue Centre
K
320
270
Hearth Depth
L
1000
950
Hearth Width
M
840
840
Hearth Projection*
N
300
300
To Flue Centre
O
503
453
Hearth Depth
P
1386
1321
To Wall Side
Q
150
100
Hearth Projection**
R
680
680
To Flue Centre
S
712
641
* Measurement taken from front feet
** Measurement taken from flue centre