All Dimension are in mm………….Copyright © 

 

3

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

 

Note: Floor Protection 

Floor

  protectors  are  normally  designed  to  suit  each  individual 

“setting”. Mnimum size is show in the specification only.

 

The 46L & 70L requires a “ASH” floor protector as needed for 
most types of freestanding wood burners.

 

Check List

 

Front Steel Baffle 

 

 

Vermiculite Board Baffle Brick 

 

  

Vermiculite Side Bricks X2

 

 

Check Door Seal

 

  

Check Damper Control

 

  

Serial Number Check

 

  

Packed By

 

  

Minimum Flue Height

 

Flue Height

 

3600

 

Measured From Top of Cabinet

 

C + 3600

 

FIREBOX DETAILS

 

FLOOR PROTECTOR ‘” ASH “ 

- Tested to ASNZS 2918

 

Description

 

 

 

46 L Fire

 

70 L Fire

 

Cabinet Width

 

A

 

650

 

750

 

Cabinet Depth

 

B

 

555

 

655

 

Cabinet Height

 

C

 

675

 

775

 

Flue Diameter

 

D

 

150

 

150

 

To Flue Centre

 

E

 

177

 

177

 

Ceiling Height

 

F

 

2400

 

2400

 

Minimum from fire to Ceiling

 

G

 

1500

 

1500

 

 

 

 

 

Emission Levels (g/kg)

 

 

 

0.86

 

 

Summary of Contents for Tasman 46L Fire

Page 1: ...ation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA SFAIT Installation Technician See www warmington co n...

Page 2: ...CIENCY BURNING SOFTWOOD 66 Council Authorisation No Ecan 111359 Nelson 111359 When Tested in Accordance with AS NZS 4012 Performance may vary from tested values depending on actual operating condition...

Page 3: ...d for most types of freestanding wood burners Check List Front Steel Baffle Vermiculite Board Baffle Brick Vermiculite Side Bricks X2 Check Door Seal Check Damper Control Serial Number Check Packed By...

Page 4: ...s walls or surfaces Ref to ASNZS 2918 2001 3 2 1 The clearance to a Non Combustible wall or surface can be less that 100mm if a wet back is not fitted and no requirement for maintenance Construction o...

Page 5: ...lite Board baffle brick in first on an angle through the door frame then repeat for the steel baffle Join the two parts together lift it up holding it horizontally resting on the one side bricks Fit b...

Page 6: ...pproximate Note Before using the Fire with a Wet Back Fitted Consult your plumber for wet back system configurations and oper ation Wet back is to be fitted to an internal heat sync before use e g Hot...

Page 7: ...be assembled with crimped ends down towards heater STAGE 7 Place Ceiling Plate over heater flue spigot ensuring the folded edge up stands are facing ceiling STAGE 8 From the roof lower Flue Pipes thr...

Page 8: ...pipe casing Note External Requirements Refer to AS NZS2918 2001 4 9 1 Install Flue system to AS NZS2918 2001 When using a rubber or Bitumen flashing Butynol Dectite an Additional Flue pipe Baffle is...

Page 9: ...oved outdoors immediately to a location clear of combustible materials 4 Cooking Because the top of the fire is in direct contact with the flame it offers a large cooking surface Ideal for entertainme...

Page 10: ...Fire Contact with your local TA Territorial Authority to check for local compliance 11 Flue System The installation and construction of the flue system must comply with ASNZS 2918 The fire requires a...

Page 11: ...mary on Setting High Temp Pain Read Stove Manufacturer instructions Babies small children pregnant women and pets should leave the area during the paint setting phase Ventilate well Paint surface will...

Page 12: ...8 2001 and the appropriate Building codes The Flue system and Fireplace is to be swept annually or more frequently if required The Appliance and Flue System has been tested to ASNZS2918 2001 WARNINGS...

Reviews: