1 September 2016
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm………...Copyright on all products ©
8
FIREBOX ACC CONCRETE HEAT CELL
The ACC Concrete Heat Cell is constructed around the firebox, using 75mm ACC Concrete.
(2400x600x75) Power Panels are required for basic heat cell construction as shown in detail “Firebox with ACC Concrete Surround”
*Note: If plastering the Heat Cell structure, it is recommended to use a fibreglass mesh with a latex plaster to minimise the chance of the plaster cracking.
(See your plasterer for correct materials and applications).
Note:
1.
All Framing is to be clear of the ACC heat
cell by 25mm
2.
All other clearances are to comply with
ASNZS:2918, and or the manufacturers in-
struction
2 x 100x100mm
Cool Air &
“Caitec Air”
external Intake
Vent each side or
in rear
Firebox
SI 1100
Surround Width
GG
1340
Surround Height
HH
1285
Surround Depth
II
635
Hearth & Plinth
75
2 x 100x100mm
Cool Air &
“Caitec Air”
external Intake
Vent each side or
in rear of the ACC
Block Heat Cell