Warmington SI 1100 Double Flue Installation Instructions Manual Download Page 10

1 September 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm………...Copyright on all products ©  

10

 

Flue 

Front Panel 

Spacer 

Adaptor 

Cap 

Cap 

HEAT SHIELD ASSEMBLY - FOR INSTALLATION INTO FRAMING  (WITH FASCIA KIT)

 

PROMINA FASCIA KIT ASSEMBLY

 

Top Panel 

Side 

Panels 

Joining 
Plate 

Step 1 :

 

Assemble  Promina  Fascia  as  shown  in  diagram  1:1 
using Joining Plate , Nuts & Bolts provided . 

Heat Shield Kit List                  Tick

 

Top Back Panel 

 1 

 

Bottom Back Panel 

 1 

 

Side Panels 

 2 

 

Front Panel 

 1 

 

Top Caps 

 2 

 

Packed By : 

  

 

Promina Fascia Kit List               Tick

 

Promina Top Panel 

 1 

 

Promina LH Side Panel 

 1 

 

Promina RH Side Panel 

 1 

 

Joining Plate 

 2 

 

Bolts & Nuts 

 8 

 

Wings 

 2 

 

Lintel Cap  

 1 

 

Packed By : 

  

 

Step 5 :

 

Assemble Front Panel 

to Heat Shield as shown 
in 5:1 & rivet in place as 
shown in diagram 5:2  

Step 6 :

 

Assemble Top Caps to 

tops of Heatshield as 
shown in diagram 6:1 . 
Rivet in place to secure 
the Top Caps as shown 

in diagram 6:2 - 6:3 .  

Cap 

Front Panel 

Diagram 

5:1 

Diagram 

6:1 

Diagram 

6:2 

Diagram 

6:3 

Diagram 

1:1 

Diagram 

1:2 

Gib Board 

Diagram  

2:1 

Step 2 :

 

Fit Promina Fascia to Firebox as shown in diagram 1:2 , 
by sliding down behind Front Flange . 

Step 3 :

 

Frameout & Gib as per Specification . 
Screw  Promina  Board  to  Framing  to 
secure in place . Butt Gib up to Promi-
na  Fascia  &  Plaster  &  Paint  as  nor-
mal .  

Assembled 

Promina 

Fascia 

Diagram 

5:2 

Summary of Contents for SI 1100 Double Flue

Page 1: ...gton Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA Installation Technician See www homeheat co nz members for a Certified NZHHA SFAI...

Page 2: ...w the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the correct position to maximise performance The Prevailing Wind Care needs to b...

Page 3: ...Peak 30 Range 14 Estimated unless stated otherwise WARMINGTON FIREBOX DIMENSION FIREBOX HEAT SHIELD CABINET Adaptor Fitting Seal Adaptor to Firebox using High temp Gasket Sealant Bolt through holes pr...

Page 4: ...ir from an external air source to ensure that the open fire has pre heated combustion air maximising efficiency while maintaining the home at constant pressure equilibrium reducing the risk of back dr...

Page 5: ...50 Heat Cell Clearance Depth P 610 Heat Cell Clearance Height Q 2203 Hearth Width R 1550 Hearth Projection S 650 Window Height V 1000 Window Width W 1350 Chimney Chase Clearance X 450 Chimney Chase Cl...

Page 6: ...0 Plinth Width T 1350 Plinth Depth U 610 Centre of Flue J 338 Chimney Chase Clearance X 450 Chimney Chase Clearance Y 1000 TIMBER PLAN FRONT ELEVATION CROSS SECTION BLOCK PLAN FRONT ELEVATION CROSS SE...

Page 7: ...se Firebox SI 1100 DF Heat cell Clearance Width OO 1210 Heat Cell Clearance Depth PP 700 Heat Cell Clearance Height QQ 2390 Hearth Width RR 1550 Hearth Projection SS 650 Window Height VV 810 Window Wi...

Page 8: ...ote If plastering the Heat Cell structure it is recommended to use a fibreglass mesh with a latex plaster to minimise the chance of the plaster cracking See your plasterer for correct materials and ap...

Page 9: ...ld secure in place with rivets as shown in diagram 4 1 Install Flue Liners over S S Flue s Step 3 Install Firebox Adaptor secure in place then Install first length of Flue s with a Spacer s at the Bot...

Page 10: ...Promina Fascia Kit List Tick Promina Top Panel 1 Promina LH Side Panel 1 Promina RH Side Panel 1 Joining Plate 2 Bolts Nuts 8 Wings 2 Lintel Cap 1 Packed By Step 5 Assemble Front Panel to Heat Shield...

Page 11: ...m 3 2 Front Panel Diagram 3 1 Front Panel Diagram 2 1 Side Panel No wings Side Panel No wings 20mm Air Gap at Bottom of Bottom Back Panel for Caitec Air Venting Top Flange Diagram 4 1 Cap Cap HEAT SHI...

Page 12: ...op Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto the liner and tighten with the screw and nut 3 Place the Flashin...

Page 13: ...ng Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Report...

Page 14: ...E VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS SETTING ADD COWL AND FLASHING CONE HEIGHT Note Flashing Spigot height is determined by...

Page 15: ...ion are in mm Copyright on all products 15 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue ex...

Page 16: ...ification All Dimension are in mm Copyright on all products 16 COMBUSTIBLE MANTLE CLEARANCES HEARTH CLEARANCES Note For Combustible Floors Minimum Hearth of 380mm A must be maintained When Raising can...

Page 17: ...nths on the firebox from original date of purchase WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4...