Warmington SI 1100 Double Flue Installation Instructions Manual Download Page 14

1 September 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm………...Copyright on all products ©  

14

 

“CHIMNEY CHASE FLASHING” AND “AIR VENTILATION” OPTIONS :

 

VENTING THROUGH CHIMNEY CHASE 

VENTING THROUGH FLASHING 

“No Insulation 
under flashing” 

“Insulation under 

flashing” 

CHIMNEY CHASE FLASHING DETAILS                                    SETTING ADD COWL AND FLASHING CONE HEIGHT

 

Note:

 

Flashing  Spigot  height  is  determined 

by the Insulation that is fitted under the 

Flashing  …  See  Details  at  bottom  of 

page.

 

STEP 1 

STEP 2 

STEP 3 

Note: Venting Spigot

 

Flashing  Venting  Spigot  is  generally 

50mm Diameter (25mm Radius) larger 
than that of the tested flues liner. The 

Venting Flashing Cone is sized to suite 
this increase.

 

Summary of Contents for SI 1100 Double Flue

Page 1: ...gton Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA Installation Technician See www homeheat co nz members for a Certified NZHHA SFAI...

Page 2: ...w the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the correct position to maximise performance The Prevailing Wind Care needs to b...

Page 3: ...Peak 30 Range 14 Estimated unless stated otherwise WARMINGTON FIREBOX DIMENSION FIREBOX HEAT SHIELD CABINET Adaptor Fitting Seal Adaptor to Firebox using High temp Gasket Sealant Bolt through holes pr...

Page 4: ...ir from an external air source to ensure that the open fire has pre heated combustion air maximising efficiency while maintaining the home at constant pressure equilibrium reducing the risk of back dr...

Page 5: ...50 Heat Cell Clearance Depth P 610 Heat Cell Clearance Height Q 2203 Hearth Width R 1550 Hearth Projection S 650 Window Height V 1000 Window Width W 1350 Chimney Chase Clearance X 450 Chimney Chase Cl...

Page 6: ...0 Plinth Width T 1350 Plinth Depth U 610 Centre of Flue J 338 Chimney Chase Clearance X 450 Chimney Chase Clearance Y 1000 TIMBER PLAN FRONT ELEVATION CROSS SECTION BLOCK PLAN FRONT ELEVATION CROSS SE...

Page 7: ...se Firebox SI 1100 DF Heat cell Clearance Width OO 1210 Heat Cell Clearance Depth PP 700 Heat Cell Clearance Height QQ 2390 Hearth Width RR 1550 Hearth Projection SS 650 Window Height VV 810 Window Wi...

Page 8: ...ote If plastering the Heat Cell structure it is recommended to use a fibreglass mesh with a latex plaster to minimise the chance of the plaster cracking See your plasterer for correct materials and ap...

Page 9: ...ld secure in place with rivets as shown in diagram 4 1 Install Flue Liners over S S Flue s Step 3 Install Firebox Adaptor secure in place then Install first length of Flue s with a Spacer s at the Bot...

Page 10: ...Promina Fascia Kit List Tick Promina Top Panel 1 Promina LH Side Panel 1 Promina RH Side Panel 1 Joining Plate 2 Bolts Nuts 8 Wings 2 Lintel Cap 1 Packed By Step 5 Assemble Front Panel to Heat Shield...

Page 11: ...m 3 2 Front Panel Diagram 3 1 Front Panel Diagram 2 1 Side Panel No wings Side Panel No wings 20mm Air Gap at Bottom of Bottom Back Panel for Caitec Air Venting Top Flange Diagram 4 1 Cap Cap HEAT SHI...

Page 12: ...op Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto the liner and tighten with the screw and nut 3 Place the Flashin...

Page 13: ...ng Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Report...

Page 14: ...E VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS SETTING ADD COWL AND FLASHING CONE HEIGHT Note Flashing Spigot height is determined by...

Page 15: ...ion are in mm Copyright on all products 15 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue ex...

Page 16: ...ification All Dimension are in mm Copyright on all products 16 COMBUSTIBLE MANTLE CLEARANCES HEARTH CLEARANCES Note For Combustible Floors Minimum Hearth of 380mm A must be maintained When Raising can...

Page 17: ...nths on the firebox from original date of purchase WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4...