29 March 2021
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
………….
Copyright ©
3
IMPORTANT NOTES:
* Inlet Pressure not to exceed 4.0KPa
GAS SPECIFICATIONS Tested to: AS 4558
NOTE : All Test Pressures are tested by a Independent Test Lab
MODLE
SG
-
EG 700
SG
-
EG 780
SG
-
EG 900
SG
-
EG 1100
SG
-
EG 600
LPG
Nominal Pressure kPa
2.75 kPa
2.75 kPa
2.75 kPa
2.75 kPa
2.75 kPa
Nominal Injector Size mm
2 X 1.1mm
2 X 1.2mm
2 X 1.3mm
2 X 1.4mm
2x 1.0 mm
Burner Pressure High kPa
2.5
2.5
2.5
2.5
2.50
Burner Pressure Low kPa
0.75
0.75
0.75
0.75
0.75
MJ/h
29
38
42
50
26
Flame Effect Output Only
Effect
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
3/8”
1/2”
1/2”
3/8”
Natural Gas
Nominal Pressure kPa
1.5 kPa
1.5 kPa
1.5 kPa
1.5 kPa
1.5kPa
Nominal Injector Size mm
2 X 1.8mm
2 X 2mm
2 X 2.2mm
2 X 2.4mm
2x1.6 mm
Burner Pressure High kPa
1
1
1
1
1
Burner Pressure Low kPa
0.3
0.3
0.3
0.3
0.3
MJ/h
35
41
48
60
27
Flame Effect Output Only
Effect
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
1/2”
1/2”
1/2”
3/8”
Lab. Test No
GL 923
GL 900
GL 834
GL 876
CUB 008
Lab. Test Dates
20/04/2010
26/02/10
26/06/09
24/12/09
13/08/2015
ESS Declaration No:
1149420106
1149520106
1149720106
1149820106
n/a
RAISED HEARTH CLEARANCES
Note: for combustible floors
Minimum Hearth of 300mm (A) must be
maintained at any given height.