16 December 2014 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm……. Copyright on all products and Specifications © 

 

WARMINGTON NOUVEAU FIREBOX DIMENSIONS

 

ACC CONCRETE SURROUND DETAILS DIMENSIONS

 

Minimum Flue Height

 

  

Flue Height 

2400 

Measured From Top of Adaptor 

B + F + 2400 

ACC CONCRETE HEARTH DIMENSIONS

 

Check List

 

 

 

Firebox 

 

 

Ash Pan 

 

 

Rack/Hotplate & Grill 

 

 

Weather Shield 

 

 

Badge 

 

 

Adaptor & Bolts 

 

 

Davit Rods 

 

 

Packed by 

 

 

Note:

 

Firebox is recessed 40mm into ACC Surround.

 

Timber Framing requires 30mm clearances with ACC 
Surround .

 

Description 

 

 

SN 1500  SN 1800  SN 2000 

SN 1250 

Firebox Width 

1500 

1800 

2000 

1250 

Firebox Height 

910 

910 

910 

910 

Firebox Depth 

600 

600 

600 

600 

Flange Width 

1550 

1850 

2050 

1300 

Flange Height 

935 

935 

935 

935 

Adaptor Height 

480 

480 

538 

480 

Pizza Oven Width 

AA 

470 

470 

470 

470 

Pizza Oven Height 

BB 

129 

129 

129 

129 

Pizza Oven Depth 

CC 

311 

311 

311 

311 

Description 

 

 

SN 1500

 

SN 1800

 

SN 2000 

SN 1250

 

Surround Width 

G

 

1710 

2010 

2210 

1460 

Surround Height 

H

 

1640 

1640 

1690 

1640 

Surround Depth 

I

 

770 

770 

770 

770 

Window Width 

J

 

1560 

1860 

2060 

1310 

Window Height 

K

 

940 

940 

940 

940 

*

 To Centre of Flue 

N

 

450 

450 

450 

450 

Between Flue Centre 

O

 

760 

760 

842 

600 

Flue Diameter X 2 

P

 

300 

300 

350 

250 

Liner Diameter X 2 

Q

 

400 

400 

450 

350 

*

 Flue Centre 

400 

400 

382 

400 

Description 

 

 

SN 1500

 

SN 1800

 

SN 2000 

SN 1250

 

Hearth Width 

L

 

1900 

2200 

2400 

1650 

Hearth Projection 

M

 

850 

850 

850 

850 

Note : 

* “Z” dimension is from Flue Centre to Firebox Front Flange Not 

including 40mm rebate from ACC Enclosure . 

 
* “N” dimension is from Flue Centre to the ACC Enclosure front 

Summary of Contents for Nouveau Pizzeria SN1250 Double Flue

Page 1: ...ns for further reference Ensure that you have the correct and current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Install...

Page 2: ...ce To be maintained to the manufactures Instructions Installation Notes A rebate of 40mm is recommended from the front face of the surround to the front of the fire to reduce the ingress of water into...

Page 3: ...10 910 Firebox Depth C 600 600 600 600 Flange Width D 1550 1850 2050 1300 Flange Height E 935 935 935 935 Adaptor Height F 480 480 538 480 Pizza Oven Width AA 470 470 470 470 Pizza Oven Height BB 129...

Page 4: ...ith the bolting point provided on the Left and Right hand sides of the fire box seismic restraints 4 Fit the Adaptor to the Fire box Ensure that exhaust sealant is used between the fire and Adaptor Bo...

Page 5: ...rtant Notes All Framing Dimensions are Internal Only All Timber Framing Cladding must be constructed to suit an Outdoor Environment as per NZ Building Code Firebox is recessed 40mm into ACC Surround T...

Page 6: ...arth Projection SS 850 850 850 850 Plinth Width TT 1610 2010 2410 1410 Plinth Depth UU 700 700 700 700 Centre of Flue NN 450 450 450 450 TIMBER PLAN FRONT ELEVATION CROSS SECTION Important Note All Lo...

Page 7: ...tion SS 850 850 850 850 Window Height VV 940 940 940 940 Window Width WW 1560 1860 2060 1310 Note Ensure that the Fire and Flue System is Installed before the Alcove access is blocked off Block module...

Page 8: ...C Heat cell is constructed around the firebox using 75mm ACC see attached minimum spec below 2400x600x75 Power Panels are required for basic heat cell construction as shown in detail Firebox with Hebe...

Page 9: ...t cell construction as shown in detail Firebox with ACC Surround Note If plastering the Heat Cell structure it is recommended to use a fibreglass mesh with a latex plaster to minimise the chance of th...

Page 10: ...hat the flue pipe is 5mm lower that the Flashing cone 2 Fit the Top Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto...

Page 11: ...men flashing Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 T...

Page 12: ...Y CHASE FLASHING DETAILS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING AND AIR VENTILATION OPTIONS Note Flashing...

Page 13: ...are in mm Copyright on all products and Specifications 13 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined The flue...

Page 14: ...imension are in mm Copyright on all products and Specifications 14 Important Note All Load Bearing Structures are to be Engineered to carry load RAISED HEARTH CLEARANCES Mantle Clearances Firebox Y Z...

Page 15: ...AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING WARNING DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES WARNING WHEN OPERATION THIS APPLIANCE AS AN OPEN FIRE USE A SPARK SCREEN...

Reviews: