Warmington Nouveau BBQ 900 Installation Instructions Manual Download Page 7

9 June 2017

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notifi-

All Dimension are in mm……. Copyright on all products and Specifications © 

 

7

 

Height of 

Blocks to suit 

2.4m Fluekit & 

S/S Flashing 

Warm Air Vent

 

BLOCK ALCOVE  & TRIM OUT DETAILS

 

MINIMUM HEAT CELL BLOCK ALCOVE CLEARANCES 

 

Note:

 

Centre Line of Flue is `NOT’ in Centre 

of Alcove

 

Firebox

 

 

 

SN 

900

 

SN 

1100

 

SN 

1250

 

SN 

1500

 

Plinth Width 

TT

 

1210  1210  1610  1610 

Plinth Depth 

UU

 

600 

600 

700 

700 

Hearth Width 

RR

 

1590  1650  1650  1900 

Hearth Projection 

SS

 

380 

380 

850 

850 

Window Height 

VV

 

790 

790 

940 

940 

Window Width 

WW

 

960 

1160  1310  1560 

Note:

 

Ensure that the Fire and Flue System is Installed before the Alcove access is blocked off. 

Block modules may vary to the drawing see Blocklayer for further details . 

All Load Bearing Structures are to be Engineered to carry load . 

Cool air  ex-
ternal intake 
vent

 

Height of 

Blocks to suit 

2.4m Fluekit & 

S/S Flashing 

See Page 12 for 

S/S Flashing 
Detail & correct 
Spigot Heights 

Note:

 

Firebox is recessed 40mm into Non 

Combustible Surround.

 

UU 

UU 

TT 

Summary of Contents for Nouveau BBQ 900

Page 1: ...current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www homeh...

Page 2: ...d to the manufactures Instructions Installation Notes A rebate of 40mm is recommended from the front face of the surround to the front of the fire to reduce the ingress of water into the fire Due to t...

Page 3: ...eight H 1325 1640 1640 1325 Surround Depth I 635 770 770 660 Window Width J 960 1560 1310 1160 Window Height K 790 940 940 790 To Centre of Flue N 312 387 448 312 Flue Diameter O 300 450 350 350 Liner...

Page 4: ...through to the floor with the bolting point pro vided on the Left and Right hand sides of the fire box seismic restraints 4 Fit the Adaptor to the Fire box Ensure that exhaust sealant is used between...

Page 5: ...adding must be con structed to suit an outdoor environment as per NZ building code Firebox is recessed 40mm into Hebel Surround External air intake vent required 2x 100mm diame ter at the base CAITEC...

Page 6: ...48 387 BLOCK PLAN FRONT ELEVATION CROSS SECTION Note Centre Line of Flue is NOT in Centre of Alcove Firebox SN 900 SN 1100 SN 1250 SN 1500 Hearth Width RR 1590 1650 1650 1900 Hearth Projection SS 380...

Page 7: ...h Width TT 1210 1210 1610 1610 Plinth Depth UU 600 600 700 700 Hearth Width RR 1590 1650 1650 1900 Hearth Projection SS 380 380 850 850 Window Height VV 790 790 940 940 Window Width WW 960 1160 1310 1...

Page 8: ...breglass mesh with a latex plaster to minimise the chance of the plaster cracking See your plasterer for correct materials and applications Note HEBEL KITSET ASSEMBLY Details When purchasing the Hebel...

Page 9: ...assembly guide comes with the Kit These Hebel Kits are not designed to be load bearing HEBEL HEAT CELL CUT SIZES FROM PANELS for SN1500 The Hebel Heat cell is constructed around the firebox using 75m...

Page 10: ...are fitted that the Top of the Flashing Cone and the Flue Pipe are flush or that the Flue Pipe is 5mm lower than the Flashing cone 2 Fit the Top Spider into position ensure that the legs of the Spider...

Page 11: ...ashing Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Re...

Page 12: ...SE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS Note Flashing Spigo...

Page 13: ...opyright on all products and Specifications 13 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The Flu...

Page 14: ...n all products and Specifications 14 Note For Combustible Floors Minimum Hearth of 380mm A must be maintained Combustible Floor Important Note All Load Bearing Structures are to be Engineered to carry...

Page 15: ...n matter by lighting or igniting the fire or Burner ENSURE THAT THE OUTDOOR FIRE IS WELL VENTILATED WHEN LIGHTING FOR THE FIRST TIME and operate fire on high for up to 5 minutes Cooking may proceed af...

Reviews: