Warmington Nouveau BBQ 900 Installation Instructions Manual Download Page 1

9 June 2017

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notifi-

All Dimension are in mm……. Copyright on all products and Specifications © 

 

1

 

Outdoor BBQ Cooking Fire

Wood Burner

 

Installation Instructions

 

Nouveau BBQ 900

-

1100

-

1250

-

1500 Single Flue

 

 

                                

Visit 

www.warmington.co.nz

 

for Spec’s, DWG’s and PDF uploads of Fires

 

 

Fire, Flue System and Instructions to Comply with ASNZS 2918:2001

 

 

Keep these Instructions for further reference……Ensure that you have the correct and current Installation details for the Warmington Fire

 

 

Installation

 

The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician .

 

See www.homeheat.co.nz/members for a Certified NZHHA SFAIT Installer in your area .

 

 

 

 

IMPORTANT 

Read all the Instructions carefully before commencing the Installation. Failure to follow these Instructions may result in a Fire Hazard and void the warranty . 

Note: FLUE SYSTEMS Casing….

 

Flue system may require to be Doubled lined to comply. 

Ref ASNZS:2918:2001 4.3 Flue pipe casing

 

Warmington 

Minimum 2.4m Fluekit 

Hebel Heat Cell 

(Not Load Bearing) 

Warmington 

Outdoor Firebox 

Hearth 

Important Note :

 

All  Load  Bearing  Structures  are 

to be Engineered to carry load .

 

Summary of Contents for Nouveau BBQ 900

Page 1: ...current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www homeh...

Page 2: ...d to the manufactures Instructions Installation Notes A rebate of 40mm is recommended from the front face of the surround to the front of the fire to reduce the ingress of water into the fire Due to t...

Page 3: ...eight H 1325 1640 1640 1325 Surround Depth I 635 770 770 660 Window Width J 960 1560 1310 1160 Window Height K 790 940 940 790 To Centre of Flue N 312 387 448 312 Flue Diameter O 300 450 350 350 Liner...

Page 4: ...through to the floor with the bolting point pro vided on the Left and Right hand sides of the fire box seismic restraints 4 Fit the Adaptor to the Fire box Ensure that exhaust sealant is used between...

Page 5: ...adding must be con structed to suit an outdoor environment as per NZ building code Firebox is recessed 40mm into Hebel Surround External air intake vent required 2x 100mm diame ter at the base CAITEC...

Page 6: ...48 387 BLOCK PLAN FRONT ELEVATION CROSS SECTION Note Centre Line of Flue is NOT in Centre of Alcove Firebox SN 900 SN 1100 SN 1250 SN 1500 Hearth Width RR 1590 1650 1650 1900 Hearth Projection SS 380...

Page 7: ...h Width TT 1210 1210 1610 1610 Plinth Depth UU 600 600 700 700 Hearth Width RR 1590 1650 1650 1900 Hearth Projection SS 380 380 850 850 Window Height VV 790 790 940 940 Window Width WW 960 1160 1310 1...

Page 8: ...breglass mesh with a latex plaster to minimise the chance of the plaster cracking See your plasterer for correct materials and applications Note HEBEL KITSET ASSEMBLY Details When purchasing the Hebel...

Page 9: ...assembly guide comes with the Kit These Hebel Kits are not designed to be load bearing HEBEL HEAT CELL CUT SIZES FROM PANELS for SN1500 The Hebel Heat cell is constructed around the firebox using 75m...

Page 10: ...are fitted that the Top of the Flashing Cone and the Flue Pipe are flush or that the Flue Pipe is 5mm lower than the Flashing cone 2 Fit the Top Spider into position ensure that the legs of the Spider...

Page 11: ...ashing Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Re...

Page 12: ...SE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS Note Flashing Spigo...

Page 13: ...opyright on all products and Specifications 13 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The Flu...

Page 14: ...n all products and Specifications 14 Note For Combustible Floors Minimum Hearth of 380mm A must be maintained Combustible Floor Important Note All Load Bearing Structures are to be Engineered to carry...

Page 15: ...n matter by lighting or igniting the fire or Burner ENSURE THAT THE OUTDOOR FIRE IS WELL VENTILATED WHEN LIGHTING FOR THE FIRST TIME and operate fire on high for up to 5 minutes Cooking may proceed af...

Reviews: