29 March 2021

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

………….

Copyright © 

 

3

 

Firebox

 

 

 

SG/EG

 

SN 1250

 

SG/EG

 

SN 1500

 

Firebox Width

 

A

 

1250

 

1405

 

Firebox Height

 

B

 

600

 

600

 

Firebox Depth

 

C

 

435

 

435

 

Flange Width

 

D

 

1350

 

1500

 

Flange Height

 

E

 

650

 

650

 

Insulation Kit Width

 

F

 

1342

 

1490

 

Insulation Kit Height

 

G

 

1220

 

1220

 

Insulation Kit Depth

 

H

 

565

 

565

 

Centre of Flue

 

I

 

360

 

360

 

Flue

 

J

 

300

 

300

 

Flue Liner

 

K

 

350

 

350

 

Fascia Width

 

L

 

1410

 

1560

 

Fascia Height

 

M

 

680

 

680

 

Fascia Section

 

N

 

80

 

80

 

Heat Output

 

kW

   

 

Range*

 

  

9

-

10

 

10

-

11

 

*Estimated unless stated otherwise.

 

WARMINGTON FIREBOX DIMENSION

 

Minimum Flue Height

 

 

 

Flue Height

 

3600

 

Measured From Top of Firebox

 

B + 3600

 

FIREBOX HEAT CELL CABINET

 

Note:

 

DO NOT FRAME OUT TO THESE DIMENSIONS CHECK HEAT 

CELL ALCOVE ON PAGE 5 & 6.

 

Seismic Restraint

 

Secure Firebox through anchor positions provided 

-

 through 

base of Fire.

 

Stainless Steel

 

Insulation Kit

 

Weathershield lip

 

Summary of Contents for EG 1250

Page 1: ...urrent installation details for the Warmington fireplace Installation The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician See www ho...

Page 2: ...uately vent the building or some mechanical system to ensure that there is always a neutral or positive pressure at the fireplace and a negative pressure at the flue outlet This will ensure that the d...

Page 3: ...Height G 1220 1220 Insulation Kit Depth H 565 565 Centre of Flue I 360 360 Flue J 300 300 Flue Liner K 350 350 Fascia Width L 1410 1560 Fascia Height M 680 680 Fascia Section N 80 80 Heat Output kW R...

Page 4: ...a Burner Pressure Low kPa 0 75 kPa 0 75 kPa MJ h 60 70 Flame Effect Output Only Effect Effect Supply Pipe Size dia min 1 2 1 2 Natural Gas Nominal Pressure kPa 1 5 kPa 1 5 kPa Nominal Injector Size mm...

Page 5: ...dth O 1362 1510 Heat Cell Clearance Height P 1240 1240 Heat Cell Clearance Depth Q 615 615 Hearth Width R 1750 1900 Hearth Projection S 300 300 Chimney Chase Clearance T 450 450 Window Height V 660 66...

Page 6: ...Firebox SG EG SN 1250 SG EG SN 1500 Plinth Width OO 1610 1610 Plinth Depth QQ 600 600 Hearth Width RR 1750 1900 Hearth Projection SS 300 300 Centre of Flue II 360 360 Firebox SG EG SN 1250 SG EG SN 1...

Page 7: ...ETAILS MINIMUM HEAT CELL BLOCK ALCOVE CLEARANC ES Note Ensure that the Fire and Flue System is Installed before the alcove access is blocked off Block modules may vary to the drawing Please talk to yo...

Page 8: ...THE WEATHERSHIELD The Nouveau Gas fireplace is packaged with the weathershield fitted to the firebox and since the fascia is not installed during shipping the weathershield cams will not fit after the...

Page 9: ...CONE IS NEEDED 1 NOTE The last length of flue pipe needs to extend past the liner so that when the top spider and the Flashing cone are fitted that the flashing cone and the flue pipe are flush or th...

Page 10: ...1041 20th July 2004 FLUE PENETRATION vented through alcove double lined flue system FLUE PENETRATION Vented through Top Flashing Note External requirements Refer to relevant standards Install flue sys...

Page 11: ...CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE No Insulation under flashing VENTING THROUGH FLASHING Insulation under flashing Note Flashing spigot height is determined by t...

Page 12: ...ange product specifications without prior notification All Dimension are in mm Copyright 12 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE 3D View The flue exit is to com...

Page 13: ...TD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 13 COMBUSTIBLE MANTLE CLEARANCES Note For Combustible Floors Minimum Hearth of 300mm...

Page 14: ...pecified on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation Cavity through th...

Page 15: ...e 2 top rows of coals onto the bottom row Each Coal randomly positioned with the Torn roughest Face Outward Ensure Coal positioning does not directly block the 3 Flame Pilot The placement of the Coals...

Page 16: ...ht all the way across Once the flame is established adjust to the desired setting and close the cover To shut down Open the cover by pulling it outwards Turn the control ignition switch to PILOT and t...

Page 17: ...ipment and Secure Test Nipple Check Valve Burner for Correct Operation check Fire for Gas Leaks Adjustment of High Low Settings Must be Carried out by a Certified Gas Fitter Only Note When the Base sc...

Page 18: ...ing appliance or open fire Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build up of hazardous gases within the room The fire is not intended for the d...

Page 19: ...he hi kPa value in the table for maximum output test point inlet Modulator Harness Connections 1 2 BSPT gas outlet SIT 840 Control Valve test point outlet 1 2 BSPT gas inlet adjustment screw After che...

Page 20: ...21 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 20 ON OFF SWITCH SIT 840 WIR...

Page 21: ...crew B to Increase the Pressure and Screw it Out to Decrease the Pressure Carefully replace the Modulator Plas tic Cap Set the pressure to the hi kPa value in the table for maximum output The burner w...

Page 22: ...1 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 22 HIGH LOW SWITCH SIT 845 WI...

Page 23: ...OK to accept The days of the week will begin to flash Setting the day of the week function Press and release the or button to change the day of the week to the following or previous day Press and hol...

Page 24: ...day s of the week press OK First period s start time The display will indicate P1 on the top The Hour and AM PM settings will now flash To set the P1 starting time Press and release the or button to i...

Page 25: ...Google Play Store https play google com store apps details id com millec intelligythermostatmkii For instructions on how to push the appliance to your Wi Fi please go to the Warmington website and fi...

Page 26: ...ll ignite first and once this is on it will ignite the main burner Pressing and releasing the power button again will switch off the appliance When the appliance is turned on the gas fire will be set...

Page 27: ...E Any alterations to pressure is to be carried out by a Certified Gasfitter If adjustments are necessary remove the cap The Pressure Adjustment screw and nut are on the front side of the Gas Control V...

Page 28: ...e Diagram B above Turn the appliance on and off a few times to check ignition When you are satisfied that the appliance is working correctly fit the front panel back to the Gas Burner NOTE Ensure you...

Page 29: ...Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 29 FULLY MODULATING SIT 845 WI...

Page 30: ...dards and the appropriate building codes This appliance must be serviced annually and any service operation must be carried out by a qualified service person Warranty cover will be considered void if...