4
installation.
●
Natural Gas Fire Pit:
Supply Pressure: Minimum: 3.5” W.C.; Maximum: 5.0” W.C.
Outlet Pressure: 3.5” W.C.
●
LP Gas:
Supply Pressure: Minimum: 10.0” W.C.; Maximum: 11.0” W.C.
Outlet Pressure: 10.0” W.C
2) Location
Warning:
All fire pits, match lit kits, spark ignition, safety pilot and
electronic ignition systems are designed and intended for outdoor use
only.
Warning:
For electronic ignition models there must be an electrical
shut off ( wall switch or breaker ) on the exterior of the fire pit or on
adjacent wall to allow for emergency shutdown and maintenance.
Warning:
All fire pits must have a gas shutoff on the outside of the
exterior of the fire pit to allow for emergency shut off and maintenance.
Warning:
Select a location where the fire pit can be attended during
operation. Never leave an operating fire pit unattended or by someone
not familiar with its operation or emergency shut off locations.
Warning:
Both children and adults should be alerted to the hazards
of high surface temperatures and should stay away to avoid burns and
clothing ignition.
Warning:
Young children should be carefully supervised when they
are in the area of fire pit.
Warning:
Clothing or other flammable materials should not be
placed on or near fire pit.
Warning:
Fire pits create very high temperatures - Combustibles
must be located far enough away that there is no risk of ignition.
IMPORTANT:
It is recommended that material such as granite, marble
or other dense stone be kept away from 6-10” from flame due to risk of
cracking. Manufacturer is not responsible for damage.
Fire Pit Clearances – See Figures 1 and 2 On Last Pages
•
Under Valve Box When Applicable 2” For Drainage
•
Sides Surrounding Fire Pit 36” From Structure or
Combustibles
•
Overhead Clearance 120” Over Head
•
Select a location with good drainage.
•
Choose a location that allows easy access for installation and
maintenance of the fire pit.
•
Pick a location that allows sufficient horizontal room to enjoy the
fire pit while allowing a safe distance from the heat and flame .
Summary of Contents for CFB60LP
Page 1: ... 1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60 24V LP NG DMLS60 3V LP NG MLS60 LP NG ...
Page 17: ... 17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System ...
Page 18: ... 18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System ...
Page 19: ... 19 MLS60 with LP or NG Regulator ...
Page 20: ... 20 System Tags and Markings ...
Page 21: ... 21 ...
Page 22: ... 22 ...
Page 23: ... 23 ...