background image

   

4   

installation. 

 Natural Gas Fire Pit: 

        Supply Pressure: Minimum: 3.5” W.C.; Maximum: 5.0” W.C. 
        Outlet Pressure: 3.5” W.C. 

 LP Gas: 

       Supply Pressure: Minimum: 10.0” W.C.; Maximum: 11.0” W.C. 
       Outlet Pressure: 10.0” W.C

 

 
2) Location 

Warning: 

All fire pits, match lit kits, spark ignition, safety pilot and 

electronic ignition systems are designed and intended for outdoor use 
only. 

Warning: 

For electronic ignition models there must be an electrical 

shut off ( wall switch or breaker ) on the exterior of the fire pit or on 
adjacent wall to allow for emergency shutdown and maintenance. 

Warning: 

All fire pits must have a gas shutoff on the outside of the 

exterior of the fire pit to allow for emergency shut off and maintenance. 

Warning: 

Select a location where the fire pit can be attended during 

operation. Never leave an operating fire pit unattended or by someone 
not familiar with its operation or emergency shut off locations. 

Warning: 

Both children and adults should be alerted to the hazards 

of high surface temperatures and should stay away to avoid burns and 
clothing ignition. 

Warning: 

Young children should be carefully supervised when they 

are in the area of fire pit. 

Warning: 

Clothing or other flammable materials should not be 

placed on or near fire pit. 

Warning: 

Fire pits create very high temperatures - Combustibles 

must be located far enough away that there is no risk of ignition. 

IMPORTANT:

 It is recommended that material such as granite, marble 

or other dense stone be kept away from 6-10” from flame due to risk of 
cracking. Manufacturer is not responsible for damage. 

Fire Pit Clearances – See Figures 1 and 2 On Last Pages 

 

Under Valve Box When Applicable           2” For Drainage 

 

Sides Surrounding Fire Pit                      36” From Structure or                
Combustibles 

 

Overhead Clearance                              120” Over Head 

 

 

Select a location with good drainage. 

 

Choose a location that allows easy access for installation and 
maintenance of the fire pit. 

 

Pick a location that allows sufficient horizontal room to enjoy the 
fire pit while allowing a safe distance from the heat and flame . 

Summary of Contents for CFB60LP

Page 1: ... 1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60 24V LP NG DMLS60 3V LP NG MLS60 LP NG ...

Page 2: ...he vicinity of this or any other appliance Danger If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from appliance and immediately call gas supplier or fire department INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Instructions are also available at www warming trends com Index 1 General Info 2 Lo...

Page 3: ... fire pit is not in use via wall switch or breaker Warning We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in Canada by WETT Wood Energy Technical Training In...

Page 4: ...g Both children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns and clothing ignition Warning Young children should be carefully supervised when they are in the area of fire pit Warning Clothing or other flammable materials should not be placed on or near fire pit Warning Fire pits create very high temperatures Combustibles must be locat...

Page 5: ...ased on material size and extended use The vent may work as a drain as well when installed at bottom sidewall to prevent water build up Warning The interior void space of the enclosure surrounding the valve box cannot be filled with any material gravel crushed rock concrete etc It is a requirement to have a minimum of 6 under the valve box for proper ventilation Warning Select materials that are n...

Page 6: ...e followed Warning Gas Plumbing Connections Use only joint compound or tape that is resistant to all gases Apply joint compound to all male pipe fittings only DO NOT use on FLARED fittings Be sure to tighten every joint securely Warning For systems with an extended or detached valve box the area in which the valve box is installed must conform with all installation requirements to include but not ...

Page 7: ...OVER 1 2 MAY CREATE BACK PRESSURE AND GAS LEAKAGE FROM AIR MIXER RESULTING IN LP POOLING UNDER FIRE PIT Warning FOR GLASS MEDIA USAGE WITH LP GAS THE UNIT MUST BE TESTED WITH MEDIA OVER BURNER FOR CONFIRMATION OF NO BACK PRESSURE CREATING GAS TO LEAK OUT OF AIR MIXER VENTURI HOLES THIS MAY HAVE TO BE DONE PRIOR TO PLACING IN ENCLOSURE IF NO ACCESS DOOR Warning The fire pit is designed to use appro...

Page 8: ...n 1 below crossfire burner jets For Electronic Ignition 3 PILOT ASSEMBLY SCREEN Do not cover pilot assemble screen or opening with lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition OPTIONAL Placing Fire Logs 4 Place approved logs on top of lava rock base ...

Page 9: ...ith lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition DO NOT COVER PILOT SCREEN DO NOT COVER PILOT OPENING 6 Parts List 1 Fire Pit and or MLS60 and Electronic Control Systems Crossfire Burner CFB60 Aluminum Plate ALP Honeywell Electronic Ignition System 24VIK Includes gas valve pilot assembly and ignition control ...

Page 10: ...Octagon Fire Pit 36SFP 36 Square Fire Pit 42SFP 42 Square Fire Pit 36FP 36 Round Fire Pit 42RFP 42 Round Fire Pit 4830RFP 48 x 30 Rectangle Fire Pit 42RBF Red Brick Schoolhouse 42 Fire Pit HOLLY60 Hollyhock Sculptural Fire Pit SBGH L Solid Black Granite Hearth Fire Pit SBGH R Solid Light Granite Hearth Fire Pit TAIL60 The Tailgater Portable Copper Fire Pit TAIL PC60 The Tailgater Coated Aluminum C...

Page 11: ... 36 Simplicity Fire Bowl CSIMP40 40 Simplicity Fire Bowl HALO36 36 Halo Fire Bowl HALO48 48 Halo Fire Bowl ELEVATED HALO36 36 Elevated Halo Fire Bowl ELAVATED HALO48 48 Elevated Halo Fire Bowl SPIRE Fire Spire FIRECUBE Fire cube HEMI 26 26 Hemi Fire Bowl HEMI 36 36 Hemi Fire Bowl FIREBOX 30 30 Firebox FIRETABLE Fire Table FIRETROUGH Fire Trough Note All models may contain one of the burners listed...

Page 12: ...ittings and connections 6 For LP models check back pressure with media installed This may need to be done with the pit outside of the enclosure 8 Fire Pit Operation Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Warning If using an LP bottle position at safe distance away from flame Warning Do not place...

Page 13: ...o vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in section 2 Selecting the Location Warning If lava rock is wet allow fire pit to burn for 45 minutes prior to coming within 15 feet of the fire pit Warning When fire pit is not in operation turn off gas valve WARRANTY REQUIREMENT When not in use the fire pit must be covered ...

Page 14: ...r several tries turn the key valve to the OFF position and call your service technician or gas supplier 5 Never leave fire pit unattended by an adult TO TURN OFF GAS APPLIANCE 1 Turn key valve counterclockwise until it stops 2 Carefully verify flame is OUT 3 After cooling cover fire pit with vinyl cover ...

Page 15: ...oving the logs and media to allow access to burner Use a paperclip and carefully insert in jet to remove dust spider webs and loose particles from base logs and crossfire burner itself If evidence of damage crossfire burner must be replaced with crossfire burner specified by manufacturer Thermocouple Cleaning of Soot 1 x 6 mos or as needed Remove lava rock glass around pilot then the blow out box ...

Page 16: ...manufacturing defects that prevent safe and correct function as follows Electronics Gas Valve Pilot Assembly Commercial 6mos Residential 1 yr Aluminum plate Brass Crossfire Burner LIFETIME This commences from the date of original sale shipment from Warming Trends FOB Littleton Colorado This warranty is for parts and in house Warming Trends labor The defective product must be sent back to Warming T...

Page 17: ... 17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System ...

Page 18: ... 18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System ...

Page 19: ... 19 MLS60 with LP or NG Regulator ...

Page 20: ... 20 System Tags and Markings ...

Page 21: ... 21 ...

Page 22: ... 22 ...

Page 23: ... 23 ...

Reviews: