23
warmhaus.co.uk
3.13. Plume Displacement Kits Ø60 mm
Elbow( 87 ), Plume
87
45
87
Product Name
Product Code
3.14. Recommendations of Plume Kit Installation
NOTE: Due to the nature of the boiler a plume of water vapour will be
discharged from the flue. This should be taken into account when siting
the flue terminal.
1. The following guidelines indicate the general requirements for siting
balanced flue terminals. For GB recommendations are given in BS 5440
Pt 1. For IE recommendations are given in the current edition of I.S. 813
“Domestic Gas Installations”.
2. If the terminal discharges onto a pathway or passageway, check that
combustion products will not cause a nuisance and that the terminal will
not obstruct the passageway.
3. If a terminal is less than 2 metres above a balcony, above ground or
above a flat roof to which people have access, then a suitable terminal
guard must be provided.
Opening Window
or Door
mm
MIN.
Plume
Displacement Kit
Air Inlet
IMPORTANT:
• The terminal position must ensure the safe and nuisance - free
dispersal of combustion products.
IMPORTANT:
If fitting a Plume Displacement Flue Kit, the air inlet
must be a minimum of 300 mm from any opening windows or
doors.
15311660600031
15311660600032
15311660600033
15311660600034
15311660600035
15311660600036
0058_01.D210120
0059_01.D210120
0060_01.D210120
0061_01.D210120
0062_01.D210120
0063_01.D210120
0064_01.D181001
Summary of Contents for EWA 2525C
Page 1: ...CONDENSING COMBI BOILERS INSTALLATION SERVICE MANUAL EWA 2525C 25 kW EWA 2530C 30 kW...
Page 2: ......
Page 3: ...3 warmhaus co uk...
Page 57: ...57 warmhaus co uk...