5  MAINTENANCE 

 

Isolate all electrical supplies before removing any components or before draining the cylinder or heat source circuits. 

5.1  Inspection Access 

Where  necessary,  the  internal  components  of  the  cylinder  can  be  inspected  by  means  of  the  immersion  heater  boss  (1¾”)  using  an 
appropriate inspection tool e.g. boroscope. 

5.2  Replacement Parts 

Part description 

 

 

 

 

 

Code   

Cylinder thermostat  

 

 

 

 

WDS6 

Immersion heater c/w stat (1¾”)   

 

 

3602 

This stainless steel cylinder requires no corrosion protection device e.g. anode. 

5.3  Fault Finding 

Symptom

 

Possible cause

 

Possible remedy

 

Little / no hot water flow

 

Mains water supply isolated 

 

Open stopcock.

 

Cistern ball cock failure 

 

Check ball cock in cistern tank.

 

Water from hot taps is cold

 

Boiler programmer or immersion timer not 
calling for hot water 

 

Set programmer / timer to call.

 

Cylinder thermostat high limit tripped or 
immersion thermostat high limit tripped 

 

Check and reset (refer to Section 1).

 

Heat source malfunction

 

(e.g. boiler / immersion heater / etc)

 

Check heat source – if faulty, refer to heat source manufacturer’s 
instructions.

 

Motorised valve malfunction

 

(where fitted, not supplied as standard)

 

Manually activate motorised valve.

 

If cylinder begins to heat, replace valve.

 

Circulating pump malfunction

 

Check wiring and/or plumbing connections to pump.

 

 

Summary of Contents for TR250V

Page 1: ...tallation Instructions Guarantee Registration Open Vented Cylinders Stainless Steel Water Heaters Products covered by this manual Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V LEAVE...

Page 2: ...il at the addresses below Please also refer to our website Should replacement components be required a list of available spares is provided in Section 5 2 page 8 In the unlikely event that replacement...

Page 3: ...g the immersion cover All cylinders are supplied with an immersion heater to allow the cylinder to be heated electrically The immersion heater has an immersion thermostat the temperature of which is a...

Page 4: ...ewable coil upper connection mm 532 532 532 532 F Cold inlet connection mm 482 482 482 482 G Renewable coil lower connection mm 432 432 432 432 OPERATING DATA Cold water capacity litres 180 210 250 30...

Page 5: ...e coil upper connection mm 462 532 H Cold inlet connection mm 412 482 J Renewable coil lower connection mm 362 432 OPERATING DATA Cold water capacity litres 248 298 Weight when full kg 290 350 Standin...

Page 6: ...ils must not exceed 6 bar and 120 C respectively All connection to the cylinder must be made using compression fittings All 22mm coils must be fully pumped gravity circulation is NOT suitable for the...

Page 7: ...rough the base then insert downwards into the pocket as shown in Figure 5 Anchor the cable using the clamp provided Figure 5 Solar temperature sensor installation Main lower solar sensor location Twin...

Page 8: ...Thermostat Mid position Valve 5 Amp Fused Spur Isolator Live L Neutral N Earth E Heating On X Hot Water On Y Hot Water Off Z L N E N N N N N N N N N 2 E E E E L L L X Y 1 3 L G N E 3 2 B E O N G L E O...

Page 9: ...sible cause Possible remedy Little no hot water flow Mains water supply isolated Open stopcock Cistern ball cock failure Check ball cock in cistern tank Water from hot taps is cold Boiler programmer o...

Page 10: ...e case of defects arising from normal deterioration or improper or faulty handling or processing of the unit by the customer 2 4 consequential losses however caused 3 If within the 2 year guaranteed p...

Reviews: