INSTALLATION AND REGISTRATION 

This  appliance  must  be  installed  as  described  herein  and  the  Guarantee  Registration  section 
completed and returned to the manufacturer with proof of purchase (e.g. receipts / invoices). 

The complete guarantee policy statement is included in Section 6, page 9. 

 

FAILURE TO CORRECTLY INSTALL AND REGISTER THIS PRODUCT WILL 

INVALIDATE ALL GUARANTEES 

 

 

 

 

TECHNICAL, SPARES & GUARANTEE CLAIMS 

For technical advice about the installation or use of this appliance, please contact the Warmflow 
Customer Care Centre by post, phone, fax or email at the addresses below.  Please also refer 
to our website. 

Should  replacement  components  be  required,  a  list  of  available  spares  is  provided  in  Section 
5.2, page 8. 

In  the  unlikely  event  that  replacement  components  might  be  required  within  the  guarantee 
period,  please  notify  the  Customer  Care  Centre  in  writing,  by  post,  fax  or  email,  stating  the 
nature of the fault and the part number of the replacement components required. 

 

 

Warmflow Customer Care Centre 

Warmflow Engineering 
Lissue Industrial Estate 
Moira Road 
Lisburn 
BT28 2RF 
Northern Ireland 

Telephone 

United Kingdom: 

 

028 9262 1515 

Republic of Ireland:   

048 9262 1515 

Facsimile 

United Kingdom: 

 

028 9262 0869 

Republic of Ireland:   

048 9262 0869 

Email 

[email protected] 

Website 

www.warmflow.co.uk 

 

Summary of Contents for TR250V

Page 1: ...tallation Instructions Guarantee Registration Open Vented Cylinders Stainless Steel Water Heaters Products covered by this manual Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V LEAVE...

Page 2: ...il at the addresses below Please also refer to our website Should replacement components be required a list of available spares is provided in Section 5 2 page 8 In the unlikely event that replacement...

Page 3: ...g the immersion cover All cylinders are supplied with an immersion heater to allow the cylinder to be heated electrically The immersion heater has an immersion thermostat the temperature of which is a...

Page 4: ...ewable coil upper connection mm 532 532 532 532 F Cold inlet connection mm 482 482 482 482 G Renewable coil lower connection mm 432 432 432 432 OPERATING DATA Cold water capacity litres 180 210 250 30...

Page 5: ...e coil upper connection mm 462 532 H Cold inlet connection mm 412 482 J Renewable coil lower connection mm 362 432 OPERATING DATA Cold water capacity litres 248 298 Weight when full kg 290 350 Standin...

Page 6: ...ils must not exceed 6 bar and 120 C respectively All connection to the cylinder must be made using compression fittings All 22mm coils must be fully pumped gravity circulation is NOT suitable for the...

Page 7: ...rough the base then insert downwards into the pocket as shown in Figure 5 Anchor the cable using the clamp provided Figure 5 Solar temperature sensor installation Main lower solar sensor location Twin...

Page 8: ...Thermostat Mid position Valve 5 Amp Fused Spur Isolator Live L Neutral N Earth E Heating On X Hot Water On Y Hot Water Off Z L N E N N N N N N N N N 2 E E E E L L L X Y 1 3 L G N E 3 2 B E O N G L E O...

Page 9: ...sible cause Possible remedy Little no hot water flow Mains water supply isolated Open stopcock Cistern ball cock failure Check ball cock in cistern tank Water from hot taps is cold Boiler programmer o...

Page 10: ...e case of defects arising from normal deterioration or improper or faulty handling or processing of the unit by the customer 2 4 consequential losses however caused 3 If within the 2 year guaranteed p...