8.6
Fitting a Vertical Flue Adaptor
1.
Remove the 2 self tappers connecting the flue main body to the Kabin Pak and lift off.
It may be necessary to break the seal between the flue main body and the top of the
flue pipe.
2.
Ensure that the gap between the existing flue pipe and the top of the Kabin Pak is
properly sealed with high temperature silicone sealant.
3.
Once the flue main body has been removed fit the Kabin Pak adaptor (KPA) into
position and secure with the 2 self tapping screws. A 5” conventional flue can now be
attached.
8.7
Installation of Air Intake Duct
1.
Cut a 4” hole through the wall, minimum 300mm above the ground.
2.
Cut plastic vent tube to suit wall thickness and insert into the hole in the wall.
3.
Remove plastic air inlet cover on the burner. Attach the air intake gasket and adapter
to the burner using the screws supplied.
4.
Attach one end of the flexible duct to the burner air intake adapter using 1 no 3” jubilee
clip as supplied.
5.
Feed the flexible duct through the plastic vent tube to the outside of wall and fix to the
air intake duct using the remaining jubilee clip, cut the flexible duct to a suitable length
ensuring adequate length for rotation of burner during removal.
6.
Once the flexible duct is attached to the air intake duct, insert into the vent tube and fix
it to the wall using appropriate fixings. Ensure the perforated side of the air intake duct
is facing downwards.
Air Intake Duct
Jubilee Clip
Flexible Duct
Plastic Vent Pipe
Jubilee Clip